Step 3:
Open the tool and insert the cable so
that the tape wrap applied in Step 1 is
just behind the blades. Close the tool
(Figure 3).
Step 4:
Firmly hold the cable with one hand and
use your other hand to pull the tool along
the cable until the tool is clear of the end
of the cable (Figure 4).
Step 5:
Use scissors to remove the split sections
of the cable jacket and to cut the
strength members as flush as possible to
the cable jacket (Figure 5). Use care to
avoid damaging the buffer tube. Access
the fibers as described in SRP-004-067.
5.
Mid-span Access
Step 1:
Measure and mark the strip length
required for your application, marking
the length with wraps of electrical tape. If your cable has a toning wire, apply the tape
wraps only on the optical cable - do not cover the toning wire.
Step 2:
If applicable, separate (but leave intact the toning wire from the cable as described in
SRP-004-067. Remove any web remnants on the optical cable jacket as described in that
procedure.