CORNING SRP-004-067 Instrukcja serwisowa - Strona 3

Przeglądaj online lub pobierz pdf Instrukcja serwisowa dla Kable i złącza CORNING SRP-004-067. CORNING SRP-004-067 4 stron. Access tool for sst-drop cables

Step 3:
Separate the tool halves by fulling opening the tool - its marking arrows must be aligned -
and then press the tool halves away from each other (Figure 6).
Step 4:
Position tool over cable:
a) Align the tool half arrows and reas-
semble the tool over the cable mid-
span access area (Figure 7, top).
b) Position the tool so that its blades are
just inside one of the tape wraps
applied in Step 1 (Figure 7, middle).
c) Close the tool (Figure 7, bottom).
Step 5:
Firmly hold the cable with one hand
and use your other hand to pull the
tool along the cable until the tool's
blades are just inside of the other
tape wrap (Figure 8).
Step 6:
Open the tool and repeat Step 3 to
remove the tool from the cable.
STANDARD RECOMMENDED PROCEDURE 005-066 | ISSUE 4 | JULY 2010 | PAGE 3 OF 4
KPA-2460
Figure 6 — Tool half separation
Note blade
locations
Front edge of
tape wrap
Figure 7 — Mid-span tool placement
Figure 8 — Midspan tool use
KPA-2461
KPA-2462