KitchenAid KEBS107SSS04 Arkusz techniczny - Strona 5

Przeglądaj online lub pobierz pdf Arkusz techniczny dla Piekarnik KitchenAid KEBS107SSS04. KitchenAid KEBS107SSS04 12 stron. 7" (68.6 cm) and 30" (76.2 cm) electric single and double built-in oven
Również dla KitchenAid KEBS107SSS04: Lista części (7 strony), Instrukcja instalacji (16 strony)

KitchenAid KEBS107SSS04 Arkusz techniczny
FAILURE (Leftmost
ERROR (Rightmost
2 Clock Digits)
2 Clock Digits)
F6
E1
Systems
(continued)
E2
SUGGESTED CORRECTIVE ACTION PROCEDURE
PROCEDURE: Before proceeding, perform steps 1 through 3 of "To
Enter Diagnostics Mode."
1.
If oven is off, turn oven on and inspect all of the elements, convect
ring, bake and broil. Visually inspect all elements to ensure they are
not operating.
2.
Unplug oven or disconnect power. Wait 10 seconds.
3.
Plug in oven or reconnect power.
4.
Enter into Diagnostics mode by pressing OFF > OFF > START.
5.
Press the BAKE key to cycle the Bake relay on and off as long as
Diagnostics mode is within the first 120 seconds of powering up.
If the Bake relay does not cycle on and off, go to Step 6.
If the element does not cycle with the relay, go to Step 11.
If the element does cycle on and off, go to Step 9.
6.
Unplug oven or disconnect power for 30 seconds.
7.
Plug in oven or reconnect power.
8.
Enter the diagnostics mode described in steps 1 through 3 of "To
Enter Diagnostics Mode." Press the BAKE key and cycle relay on
and off.
If the Bake relay does not cycle on and off, go to Step 13.
If the element does not cycle with the relay, go to Step 11.
If the element does cycle on and off, go to Step 9.
9.
Enter the diagnostics mode described in steps 1 through 3 of "To
Enter Diagnostics Mode." Press the BROIL key to cycle the Broil
relays. Ensure outer broil relay energizes by inspecting the outer broil
element. Press BROIL key again for inner broil element. Ensure inner
broil relay energizes by inspecting the inner broil element.
If the Broil relay does not turn on and off, go to Step 13.
If the element does not cycle with the relay, go to Step 11.
If the element or gas valve did cycle on and off, go to Step 10.
10. Enter the diagnostics mode described in steps 1 through 3 of "To
Enter Diagnostics Mode." Press the CONVECT BAKE key to cycle
the convect bake relay on and off.
If the Convect Bake relay does not turn on and off, go to Step 13.
If the element does not cycle with the relay, go to Step 11.
If the element did cycle on and off, go to Step 11.
11. Unplug oven or disconnect power.
12. Check integrity of all harness wires and connections between the
appliance manager and the electric elements. Ensure all wiring and
connections between the appliance manager and elements, and the
appliance manager and user interface are intact and properly seated
and that no wires are shorted or damaged
If the wiring connections are not intact, go to Step 17.
If the wiring is good, go to Step 14.
13. Unplug oven or disconnect power.
14. Replace the appliance manager. Go to Step 16.
15. Unplug oven or disconnect power.
16. Replace the user interface board. Go to Step 17.
17. Replace the harness.
18. Replace all parts and panels before operating.
19. Plug in oven or reconnect power.
20. Verify operation is normal. Enter into Diagnostics mode by pressing
OFF > OFF > START and complete checks.
F6
E3
Systems
(continued)
SUGGESTED CORRECTIVE ACTION PROCEDURE
PROCEDURE: Oven is not equipped with this feature. If error occurs,
before proceeding press OFF, OFF, START to enter into Diagnostics
mode and verify the error codes. If error code returns, replace user
interface with correct control associated with this product.
LIKELY FAILURE
FAILURE (Leftmost
CONDITION
2 Clock Digits)
Cook oven over
F6
temperature
Systems
(continued)
Clean oven over
temperature
SUGGESTED CORRECTIVE ACTION PROCEDURE
PROCEDURE: Before proceeding, perform steps 1 through 3 of "To
Enter Diagnostics Mode."
1.
2.
3.
4.
5.
6.
7.
8.
9.
10. If all functions are working, the Appliance Manager and User
11. Exit Diagnostics by pressing OFF.
12. Press BAKE and ensure that the Bake relay energizes and the control
13. Unplug oven or disconnect power.
14. Remove covers for access to oven controls.
15. Replace the appliance manager. Ensure all connections are properly
16. Replace all parts and panels before operating.
17. Plug in oven or reconnect power.
18. Press BAKE and ensure that Bake relay energizes and the control
19. Unplug oven or disconnect power.
20. Replace the user interface. Ensure all connections are properly
21. Replace all parts and panels before operating.
22. Plug in oven or reconnect power.
23. Press BAKE and ensure the Bake relay energizes and the control
24. Verify operation is normal. Enter into Diagnostics mode by pressing
F6
Systems
(continued)
SUGGESTED CORRECTIVE ACTION PROCEDURE
PROCEDURE: Before proceeding, perform steps 1 through 3 of "To
Enter Diagnostics Mode." Control should immediately power up in Cavity
Size Select mode. Using key "6" (DOWN) and key "3" (UP) scroll through
to locate the corresponding cavity size.
Once located press the START key to accept the proper cavity size for
the oven being programmed. Control should reinitialize to cavity size
selected. If error returns at least 60 seconds after cavity size has been
set, go to Step 1.
1.
2.
3.
Mini oven/warm drawer
over temperature
4.
5.
6.
7.
8.
9.
10. Control may power up in Cavity Size Select mode. Set cavity size as
11. Verify operation is normal. Go to Step 1 of "To Enter Diagnostic
5
ERROR (Rightmost
2 Clock Digits)
E4
Unplug oven or disconnect power. Wait 10 seconds.
Plug in oven or reconnect power.
Enter into Diagnostics mode by pressing OFF > OFF > START.
Press BAKE. Ensure Bake relay energizes by inspecting Bake
element.
Press BROIL 1 time for outer broil element. Ensure Outer Broil relay
energizes by inspecting the Outer Broil element.
Press BROIL again for Inner Broil element. Ensure Inner Broil relay
energizes by inspecting the Inner Broil element.
Press SELF CLEAN to drive door latch to lock door. Press again to
reset door latch to normal state.
Press COOK to activate the low speed cooling fan. Press again for
high speed.
If all functions do not work properly, go to Step 13.
Interface are working properly.
enters the Bake Preheat. Wait up to 60 seconds to ensure error has
been resolved. If error returns, proceed to Step 13.
seated.
enters into Bake/Preheat. Wait up to 60 seconds to ensure error has
been resolved. If error returns, go to Step 19.
seated. Go to Step 21.
enters into Bake/Preheat. Wait up to 60 seconds to ensure error has
been resolved.
OFF > OFF > START and complete checks.
E5
Unplug oven or disconnect power. Wait 10 seconds.
Plug in oven or reconnect power.
Enter into Diagnostics mode by pressing OFF > OFF > START. Press
"6" (DOWN) once main diagnostic screen appears. Screen should
identify cavity size for oven being programmed. If this is incorrectly
shown, press CLOCK to edit current programmed size. Press "6"
(DOWN) to locate proper cavity size. Once located, press START to
accept the new cavity size. Control will reset and initialize the new
cavity size programmed. Wait for 60 seconds to ensure error has
been corrected.
If error is corrected, go to Step 8.
If error returns, go to Step 6.
Unplug oven or disconnect power.
Replace user interface ensuring all connections are properly seated
and go to Step 8.
Replace all parts and panels before operating.
Plug in oven or reconnect power.
outlined in Step 3 by locating proper cavity size and pressing START
once located. Wait for 60 seconds to ensure error has been
corrected.
Mode" and complete checks.
LIKELY FAILURE
CONDITION
User interface/
appliance manager
mismatch
No cavity size
command