Jandy Infinite WaterColors IWCP50W100 Instrukcja instalacji i obsługi - Strona 7

Przeglądaj online lub pobierz pdf Instrukcja instalacji i obsługi dla Kontroler Jandy Infinite WaterColors IWCP50W100. Jandy Infinite WaterColors IWCP50W100 12 stron. Led lighting
Również dla Jandy Infinite WaterColors IWCP50W100: Instrukcja instalacji i obsługi (12 strony), Podręcznik (2 strony)

Jandy Infinite WaterColors IWCP50W100 Instrukcja instalacji i obsługi
Jandy
Infinite WaterColors
®
NOTE
The light fixture may be replaced without removing
water from the pool.
Turn off the main electrical switch or circuit
1.
breaker, which operates the underwater light.
2.
Unscrew the special pilot screw at top of the
face ring and remove the light assembly from the
niche, and place the assembly on the deck.
WARNING
Be sure to keep the special pilot screw provided
with this underwater light. This screw mounts and
electrically grounds the housing securely to the
mounting ring and wet niche. Failure to use the screw
provided could create an electrical hazard, which could
result in death or serious injury to pool or spa users,
installers or others due to electrical shock.
3.
Remove Junction Box cover, disconnect the light
fixture wires and strain relief, and then pull the
cord out of the conduit from the niche.
4.
Feed the new light fixture cord through the
conduit from the niche to the Junction Box.
NOTE
Depending on the length of the conduit, special tools
may be required to pull the cord through the conduit.
5.
Leave at least four (4) feet of cord to coil around
the light fixture or coiled into the base of the light
niche, see Figure 1. This allows the light to be
serviced after the pool is filled with water.
6.
Cut the cord at the Junction Box, leaving at least
six (6) inches of cord to make connections.
7.
Strip six (6) inches of the outer cord jacket from
the cord to expose the three insulated wires. Be
careful not to damage the insulation on the three
(3) inner wires.
8.
Install strain relief over cord jacket and connect
the light wires to the controller, black to orange,
white to orange, and green to the ground terminal
bar. Install the junction box cover.
9.
Reinstall the light assembly into the niche and
tighten the special pilot screw.
WARNING
Use only the special pilot screw provided with this
underwater light. This screw mounts and electrically
grounds the housing securely to the mounting ring
and wet niche. Failure to use the screw provided could
create an electrical hazard, which could result in death
or serious injury to pool or spa users, installers or
others due to electrical shock.
|
Pool & Spa LED Lights
Installation and Operation Manual
10.
Fill the pool until the underwater light is
completely submerged in water before operating
the light for more than 10 seconds. Turn on main
switch or circuit breaker, which operates the
underwater light, to check for proper operation.
Refer to Section 5, Controller Wiring Options.
WARNING
Never operate this underwater light for more than
10 seconds unless it is totally submerged in water.
Without total submersion, the light assembly will get
extremely hot, which may result in serious burns or in
breakage of the bulb or lens. This may result in serious
injury to pool or spa users, installers, or bystanders or
in damage to property.
Section 5. Controller Wiring
Options
The Jandy Infinite WaterColors Pool & Spa LED Lights
are designed to be powered and operated with the Jandy
Infinite WaterColors LED Light Controller and AquaLink
RS (revision Y or later). Follow all installation and
operating instructions.
NOTE
The Jandy Infnite WaterColors LED Lights are
dimmable in the iAquaLink app and will not operate
properly with light dimmers. Do not wire the lights to
any dimming circuitry.
DO NOT CONNECT TWO OR MORE POWER
SUPPLIES IN PARALLEL.
5.1

Wiring to an AquaLink

System
The Jandy Infinite WaterColors LED Lights must be
wired into the Jandy AquaLink
AquaLink RS revision Y or later is required for operation
of the lights.
Refer to Figure 2 for the Infinite WaterColors Wiring
Diagram which shows light connections to the controller
and Aqualink system.
5.2

Wiring to the Light Controller

1.
Knock out an opening in the right compartment.
2.
Run low voltage light through a conduit
connector and secure to the enclosure.
3.
Connect the low voltage wires black to orange
and white to orange.
4.
Connect the ground wire to the bus bar.
ENGLISH
RS Control
®

RS control system.

®
Page 7