Gardena 7000/D Instrukcja obsługi - Strona 4
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Pompa wodna Gardena 7000/D. Gardena 7000/D 13 stron. Clear water submersible pump / dirty water submersible pump
The connection cable of the product cannot be replaced.
If the cable is damaged the product must be scrapped.
DANGER! Electric shock!
Risk of injury due to electric shock.
The product must be supplied through a residual
current device (RCD) having a rated residual operat-
ing current not exceeding 30 mA.
Personal safety
Leaking lubricants can contaminate the pumped liquid.
Additional safety warnings
Electrical safety
DANGER! Cardiac arrest!
This product makes an electromagnetic field while
it operates. This field may under some conditions
interfere with active or passive medical implants. To
decrease the risk of conditions that can possibly
injure or kill, we recommend persons with medical
implants to speak with their physician and the medi-
cal implant manufacturer before you operate the
product.
Swimming pools and garden ponds should be designed
according to international and national design regulations.
According to DIN VDE (German Electrical Engineers'
Association) 0620, mains power cables must not have
a smaller cross-section than the rubber-sheathed cables
of the designation H05RN-F. The cable length must be
at least 10 m.
Data indicated on the type plate must match technical
data of the mains supply.
Disconnect the product from the mains if it is not in use.
Protect plug and power cable from heat, oil and sharp
edges.
The power cable or the float switch must not be used for
mounting or relocating the pump. For submerging or lift-
2. INSTALLATION
DANGER! Electric shock!
Risk of injury due to electric shock.
v Disconnect the product from the mains before
you do installation.
Hose connections:
The hose can be connected via the 3 provided connec-
tions:
Connection nippel
(1)
25 mm (1") [ Fig. I1 ]:
With GARDENA Hose Clamp Art. 7193.
Connection nippel
(2)
32 mm (1 1/4") [ Fig. I2 ]:
With GARDENA Hose Clamp Art. 7194.
(3)
Connection thread
33,3 mm (G1) [ Fig. I3 ]:
With the Original GARDENA System.
ing / securing the pump, fix a rope to the pump's carrying
handle.
In Austria, according to ÖVE B/EN 60 555 parts 1 to 3,
pumps which are used in swimming pools and garden
ponds, and equipped with firm power cable should be fed
via an ÖVE approved isolating transformer-rated voltage
must not exceed 230 V.
In Switzerland mobile appliances which are used outdoors
must be connected via a residual-current device.
A damaged pump must not be used. Before operating the
pump look to see if there is any damage to the pump
(especially to the power cable and plug). In case of dam-
age, please have the pump checked by our GARDENA
Service Centre.
Personal safety
DANGER! Risk of suffocation!
Small parts can be easily swallowed. There is also
a risk that the polybag can suffocate toddlers. Keep
toddlers away when you assemble the product.
Never operate the product when you are tired, ill or under
the influence of alcohol, drugs or medicine.
Never operate the product with open hairs or scarfs.
Keep bystanders away from the pumped medium.
Clear the outlet line before use. Avoid running the pump
with the outlet side closed off for more than 10 minutes.
against closed delivery side of the pump.
Observe the minimum water level and the max. delivery
height (see 7. TECHNICAL DATA).
Observe the pump at all times during manual operation.
Dry-running operation causes increased wear and is to be
avoided. Therefore, in manual operation the pump must
be immediately unplugged when water fails to flow.
Take care that the pump is located where the inlet open-
ings at the suction base are not obstructed neither com-
pletely nor partly.
Stand the pump on a brick if using in a pond. Use gloves
when you remove the suction base.
Note: When using a connection with maximum hose
diameter, the pump has the maximum delivery capacity.
Pump connections for the Original Gardena System:
Hose diameter
Pump connection
13 mm (1/2")
GARDENA Pump Connection Set Art. 1750
GARDENA Tap Connector Art. 18202 with
16 mm (5/8")
GARDENA Hose Connector Art. 18216
19 mm (3/4")
GARDENA Pump Connection Set Art. 1752
Note:
The 13 mm (1/2") / 16 mm (3/4")-fittings can also be
equipped with a GARDENA Regulator Valve Art. 2942 for
13 mm (1/2")-hose and Art. 2943 for 16 mm (3/4")-hose,
so that the contents of the outlet line do not flow back
through the pump after pumping. The Regulator Valves
can be ordered from your GARDENA dealer.
11