Gardena 7000/D Instrukcja obsługi - Strona 6

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Pompa wodna Gardena 7000/D. Gardena 7000/D 13 stron. Clear water submersible pump / dirty water submersible pump

Gardena 7000/D Instrukcja obsługi
IMPORTANT!
Dispose of the product through or via your municipal
recycling collection centre.

6. TROUBLESHOOTING

DANGER! Electric shock!
Risk of injury due to electric shock.
v Disconnect the product from the mains before
you do troubleshooting.
Problem
Pump is running, but does
not deliver
Pump doesn't start or suddenly
stops during operation
Pump runs, but output suddenly
decreases
NOTE: For any other malfunctions please contact the GARDENA service department.
Repairs must only be done by GARDENA service departments or specialist dealers approved
by GARDENA.

7. TECHNICAL DATA

Clear Water Submersible Pump /
Dirty Water Submersible Pump
Rated Power
Mains voltage
Mains frequency
Connection cable length
Max. delivery capacity
Max. pressure
Possible Cause
Air cannot escape as pressure
line is closed (e. g. kinked
pressure hose).
Air locks in the suction base.
Feed impeller is clogged.
Water height falls below the
minimum water level.
Thermal overload switch has switched
the pump off due to overheating.
No power.
Dirt particles are jammed in the suction
base.
Suction base is clogged.
Unit
Value (Art. 1661)
W
300
V
230
Hz
50
m
10
l/h
7000
bar
0.5
Remedy
v Open the pressure line.
v Wait for max. 60 sec. until the pump
deaerates automatically over the
vent valve. If necessary, switch off
and start it again.
v Clean the feed impeller
(see 4. MAINTENANCE).
v Submerge the pump deeper into the
water.
v Clean the feed impeller
(see 4. MAINTENANCE).
v Observe the maximum water
temperature of 35 °C.
v Check fuse and electrical plug and
socket connections.
v Clean the suction base
(see 4. MAINTENANCE).
v Clean the suction base
(see 4. MAINTENANCE).
Value (Art. 1665)
300
230
50
10
7000
0.5
13