Before connecting the model to the electricity network
Check the data plate (positioned inside the appliance) to ascertain that the voltage
and power correspond to the local electrical requirements. If in doubt contact a
qualified electrician.

Installation Instructions

Qualified technicians must carry out the installation and electrical connections of
the appliance. We recommend that you contact our customer care center on
0860 234 481/2/3 for details of a qualified technician.
For the installer
The appliance has been manufactured as a class I, therefore earth cable is
necessary.
The connection to the mains is carried out as follows:
BROWN = L line
BLUE = N neutral
Yellow and green wire =Earth lead
The cooker hood must be installed so that that the plug is easily accessible.
An omnipolar switch with a minimum aperture of 3mm between contacts, in
line with the electrical load and local standards, must be placed between
the appliance and the network in the case of direct connection to the
electrical network.
The minimum distance between the support surfaces of the cooking pots on
the cooker top and the lowest part of the cooker hood must be at least 65
cm. If a connection flue composed of two parts is used, the upper part must
be placed inside the lower part.
Do not connect the cooker hood exhaust to the same conductor used to
circulate hot air or for evacuating fumes from other appliances generated
by other than an electrical source.