Kohler K-11831 Instrukcja instalacji
7/8" (2.2 cm) Min
1-7/8" (4.8 cm) Max
1-5/8"
(4.1 cm)
Finished Wall
1-3/8"
(3.5 cm)
1-7/16" (3.7 cm) Min
2-7/16" (6.2 cm) Max
2-3/4" (7 cm) for Standard
Installations
4-1/4" (10.8 cm) for
Installations with Stainless
Steel Vessel Lavatories

1. Prepare the Site

NOTE: The wall plate requires special framing and support
considerations. Pay special attention to minimum and maximum
faucet height recommendations noted in the roughing-in sheet.
Refer to the roughing-in dimensions for additional mounting
information.
A suggested framing example is shown. Each installation may
have different framing requirements than those shown.
Mount the control box on the wall below the lavatory or
countertop.
Construct the framing for your installation.
2. Attach the Wall Plate
NOTE: Make sure the location of the wall plate is correct before
securing it in place. The centerline of the drain and faucet should be
in line with each other.
Secure the wall plate to the studs using six wood screws (not
provided).
Kohler Co.
Six Round Holes (Typical)
Wall Plate
16"
(40.6 cm)
Screws
7" (17.8 cm)
2x4 Stud Framing
Vessel Height
3