Kohler INNATE INTELLIGENT TOILET Instrukcja instalacji - Strona 10
Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Toalety Kohler INNATE INTELLIGENT TOILET. Kohler INNATE INTELLIGENT TOILET 31 stron.
I. Inlet connection
Take inlet hose from accessory bag, connect angle valve water outlet and toilet inlet T-valve.
. Power connection
DANGER: Risk of electrical shock. For plug-in installations/wall-mounted electrical supply: connect only to
a properly-grounded, grounding-type receptacle protected by a Ground-Fault Circuit-Interrupter (GFCI).
Do not remove the grounding pin or use a grounding adapter.
DANGER: Risk of electrical shock. For hardwire installations/through-floor electrical supply:
Connect only to a properly-grounded, dedicated 220V~, 50Hz, 10A circuit protected by a Class A Ground-Fault
Circuit-Interrupter (GFCI) or Earth-leakage Circuit-Breaker (ELCB).
Note: no extended wire is allowed.
Note: receptacle without grounding wire is not allowed. (Series with power cord) plug the power cord into receptacle.
K. Power on and water on test
1 Water on first and then power on after installation.
2 Open inlet valve, plug in the socket. Toilet start water and power self-inspection, fill water tank; when heard
one "Beep", night light is OFF, indicate self-inspection is completed and the toilet is ready for use. Specific
usage refers to Homeowners Guide.
3 Refer to flush water and power on inspection manual to confirm normal flush status.
1382001-T01-A
10
Kohler Co.