I. Inlet connection
Take inlet hose from accessory bag, connect angle valve water outlet and toilet inlet T-valve.

. Power connection

DANGER: Risk of electrical shock. For plug-in installations/wall-mounted electrical supply: connect only to
a properly-grounded, grounding-type receptacle protected by a Ground-Fault Circuit-Interrupter (GFCI).
Do not remove the grounding pin or use a grounding adapter.
DANGER: Risk of electrical shock. For hardwire installations/through-floor electrical supply:
Connect only to a properly-grounded, dedicated 220V~, 50Hz, 10A circuit protected by a Class A Ground-Fault
Circuit-Interrupter (GFCI) or Earth-leakage Circuit-Breaker (ELCB).
Note: no extended wire is allowed.
Note: receptacle without grounding wire is not allowed. (Series with power cord) plug the power cord into receptacle.
K. Power on and water on test
1 Water on first and then power on after installation.
2 Open inlet valve, plug in the socket. Toilet start water and power self-inspection, fill water tank; when heard
one "Beep", night light is OFF, indicate self-inspection is completed and the toilet is ready for use. Specific
usage refers to Homeowners Guide.
3 Refer to flush water and power on inspection manual to confirm normal flush status.