ELECTRONIC CONTROL PANEL

DIGITAL DISPLAY
Displays the actual pool/spa
temperature. In select mode
displays other parameters.
SELECT/SERVICE KEY
Used to select mode of
operation and enter service
mode.
Selecting the desired mode of operation is accomplished by pressing the SELECT KEY.
Temperature Setpoint
• Temperature setpoint maximum for POOL mode is 95°F (35°C).
• Temperature setpoint maximum for SPA mode is 104°F (40°C).
To change the temperature setpoint, press the SELECT KEY until you reach either POOL or SPA. This will
prompt the control to display the current temperature setpoint. Hold either the UP or DOWN key to scroll
your desired temperature setpoint. Once your new temperature setpoint has been reached, release the UP or
DOWN key. Your new setpoint will be displayed for five seconds, then revert back to the actual pool or spa
water temperature.
Selecting Pool or Spa Mode
Press the SELECT KEY until you reach P_S. Pressing the UP or DOWN key will allow you to enter either
POOL or SPA mode. Green LED indicator lights will verify the mode selected.
FIL MODE MUST BE IN THE OFF POSITION OR A FLO3 ERROR CODE WILL BE DISPLAYED.
Selecting temperature in Fahrenheit or Celsius
The factory setting is Fahrenheit. Press the SELECT KEY until you reach F_C. Press the UP KEY to reach
Fahrenheit or the DOWN KEY to reach Celsius.
MODE SELECTION
7
POOL LED
indicates pool mode.
HEAT ON LED
indicates heat is on.
SPA LED
indicates spa mode.
INCREASE KEY
DECREASE KEY