Trouble Shooting Fault Codes

Shorted thermostat sensor
F1
F2 Open thermostat sensor
F3 EEPROM corrupted
Gas valve on fault
F4
Temperature fault
F5

TROUBLESHOOTING TIPS

Symptom
Tumbler does not turn
Probable Cause
Drive belts
Drive motor
Door switch
Electronic Control
Suggested Remedy
Check both drive belts.
Replace if failed.
Check capacitor and motor.
Replace if failed
Check door switch contacts
and adjustment. Adjust or
replace door switch.
Is electronic control closing
motor relay to power drive
motor? Check for motor light
on electronic control. If no
light change control. If light is
on, check voltage and wiring
to motor.