RAPID ADVANCE MODE

To enter the Rapid Advance mode, turn the key counter-clockwise (CCW). The Rapid Advance
setting is not marked next to the key, but turning the key CCW until it stops selects this mode.
The Rapid Advance mode can be entered from either the Idle mode or during the cycle. If the
cycle has not yet started, press the "START" button. To rapid advance to the next step in the
wash cycle, push both the "UP" and "START" buttons at the same time. The display will show
an "Ad" (advance) in the display. The washer will advance to the next bath segment. The water
will drain before the advance will occur and the time displayed may not be accurate.
Notes:
The indicator lights will show to which segment the cycle has been advanced.
The cycle will continue in rapid advance mode even if the key is turned to "RUN" and/or
removed.
Rapid advance cannot skip the final 1-minute tumble of the cycle, and the door lock may
remain activated for a couple minutes after the cycle has been completed.
The chemical injection signals will not operate in Rapid Advance mode.
To end the cycle and exit the Rapid Advance mode without waiting for the time to count down,
push and hold the STOP button for 5 seconds or more.
INJECTION SOURCE DETAILS
The washer control may be programmed to send output signals for a chemical injection system.
There is a separate terminal block for connection of the external injection signals. For the
injection sources, program codes 0 through 6 are as shown in the table below. See the
ELECTRICAL section for more information.
Dexter
Recommended
Connections
Detergent
Bleach
Starch
Sour/Softener
Controller
Injection
Programmed
Terminal Block
Signals
Circuits
1
2
3
4
5
A and B
6
C and D
0
None
A
B
C
D