Dell EMC VxRail E560F Instrukcja obsługi - Strona 19

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Serwer Dell EMC VxRail E560F. Dell EMC VxRail E560F 35 stron. Appliances on poweredge servers

Dell EMC VxRail E560F Instrukcja obsługi
Figure 10. DC PSU status indicator
1. DC PSU status indicator
Table 17. DC PSU status indicators
Convention
Power indicator pattern
A
Green
B
Flashing green
C
Flashing amber
D
Not lit

iDRAC Direct LED indicator codes

The iDRAC Direct LED indicator lights up to indicate that the port is connected and is being used as a part of the iDRAC
subsystem.
NOTE:
The iDRAC Direct LED indicator does not turn on when the USB port is used in the USB mode.
Condition
A valid power source is connected to the PSU and that the PSU is
operational.
When hot-adding a PSU, the PSU indicator flashes green. This indicates
that there is a PSU mismatch with respect to efficiency, feature set, health
status, and supported voltage. Ensure that both the PSUs are of the same
capacity.
Indicates a problem with the PSU.
CAUTION:
When correcting a PSU mismatch, replace only the
PSU with the flashing indicator. Swapping the PSU to make a
matched pair can result in an error condition and unexpected
appliance shutdown. To change from a High Output configuration
to a Low Output configuration or vice versa, you must turn off
the appliance.
CAUTION:
If two PSU are used, they must be of the same type
and have the same maximum output power.
CAUTION:
Combining AC and DC PSU is not supported and
triggers a mismatch.
Power is not connected.
Overview
19