• Use telnet or SSH to connect to a functioning IP address assigned to a network interface on the
array. Do not connect to the group IP address.
• Use the null modem cable, shipped with the array, to connect the serial port on the active
control module (ACT LED is green) to a console or a computer running a terminal emulator.
Make sure the serial line characteristics are as follows:
• 9600 baud
• One STOP bit
• No parity
• 8 data bits
• No flow control
2. Log in to an account with read-write access, such as the grpadmin account.
3. Enter the
shutdown
login: grpadmin
Password:
Welcome to Group Manager
Copyright 2001-2014 Dell Inc.
group1> shutdown
After entering the
shutdown
Do you really want to shutdown the system? (yes/no)
Halt at Fri Dec 12 09:43:44 EST 2014 -- please wait...
6932:0:logevent:12-Dec-2014 09:4-
3:44.400000:logevent.cc:238:WARNING::25.3.0: User has initiated a clean
halt restart.
Main power usage is 68.5702 watts
sbs_ship_mode: Ship Mode request sent to battery
PLEASE WAIT FOR SHIP MODE CONFIRMATION MESSAGE!!
Waiting for Ship Mode entry: 5 sec
Waiting for Ship Mode entry: 10 sec
Waiting for Ship Mode entry: 15 sec
Waiting for Ship Mode entry: 20 sec
Waiting for Ship Mode entry: 25 sec
Waiting for Ship Mode entry: 30 sec
Check peer controller completion
No peer responding, peer battery is off
Batteries are now in Ship Mode!
Placing array in standby mode. To exit standby mode press and hold a
standby switch on any controller in the array.
4. Switch off the enclosure power supplies.
If you are using a network connection, the session will be disconnected before the array is fully
Note:
shut down. Confirm that the ACT LED on each control module is off (not lit) before turning off power
to the array at the power supply.
command:
command, the system displays information similar to the following output:
1 Basic Storage Array Information
7