Managing the SMI-S Provider

Starting and Stopping the OpenPegasus CIM Server

Windows-Based Operating Systems

To start or stop the OpenPegasus CIM server:
Open the Services window and locate the cimserver service. Right-click
cimserver service and select start or stop.
Or
In the command prompt type:
net start cimserver to start a service
net stop cimserver to stop a service

Linux-Based Operating Systems

To start or stop the OpenPegasus CIM server, on a terminal window type:
cimserver to start a service
cimserver -s to stop a service
Adding or Removing a Storage Array From the
SMI-S Provider
During installation, you are prompted to enter the IP addresses into a file.
After this initial setup, the SMI-enabled client must use the SMI-S Provider
proxy server system management profile to add or remove devices.
NOTE:
When a storage array is added, the IP address of only one of the
management ports of the storage array must be supplied (and not both
management ports). Entering the IP addresses for both management ports of a
single storage array causes unpredictable behavior of the SMI-S Provider.