The S6010–ON comes from the factory with two PSUs and five fan modules installed in the chassis. The fan modules and the integrated
fan-power supply are hot-swappable.
NOTE:
To run the system, both slots must have operating fan units. If you do not install a module in each slot, either as part of
the PSU or as an independent fan module, the system shuts down in one minute.
In addition to the integrated fan/power supply modules, you can order and install fan modules separately.
The system supports two airflow direction options. Do not mix airflow types in a chassis; you can use only a single airflow direction in a
chassis. If you mismatch the airflow directions, the system powers down in one minute.
Normal—airflow is from the I/O side to the PSU side.
Reversed—airflow is from the PSU side to the I/O side.
All fans and PSUs in a configuration must be in the same airflow direction.
Environmental factors can decrease the amount of time required between fan replacements. Check the environmental factors regularly. An
increase in temperature and/or particulate matter in the air might affect performance; for example, new equipment installation.
CAUTION:
Check the fans at six-month intervals and replace them as necessary. To accurately determine replacement intervals,
regularly monitor the speeds of the cooling fans.
Topics:

Components

Fan module installation
Fan module replacement
Fan air filter replacement
Components
The following list the fan components:
S6010–ON AC power supply with integrated fan module
S6010–ON AC power supply with integrated fan module—Reverse flow
S6010–ON DC power supply with integrated fan module
S6010–ON DC power supply with integrated fan module—Reverse flow
7