Allmand Nite Lite V Series Instrukcja obsługi - Strona 5

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Przenośny generator Allmand Nite Lite V Series. Allmand Nite Lite V Series 17 stron.

Allmand Nite Lite V Series Instrukcja obsługi
SERIAL NUMBER 39-000001 AND UP 
● If you are having an issue with all four lights or multiple ones not illuminating,
ensure there is sufficient power from the generator, main breaker, & light
switches to your ballast (120/240 v)
● Low output from ballasts to lights can result in lights turning off. Voltage to each
lamp should be between 360-440 volts (+ or - 10%).
● High voltage at lamp wire (tower cord connected to capacitor) of 500volts or
better indicates a short in the tower cord.
● Once the unit is started the generator should start producing power (120/240
volts). There is a 45 second window once started that the system (SLS) looks for
generator voltage from the main breaker. Once the A/C circuit sends power from
the main breaker to the SLS, the SLS will activate all 4 light relays.
● Once the light relays are open you can then activate each light switch. Current
from the light switch should pass through the light relay and into each ballast with
capacitor. Input to each ballast is 120/240 volts and out of each lamp wire from
the capacitor is 360-440/ + or -10%.
● Each lamp should get 360-440 volts.Check power at every switch and capacitor
start to finish.
Nite Lite ​ V ​ Series  
5