Cleaning and care
Changing a halogen lamp
Before any cleaning or maintenance
work is carried out, disconnect the
cooker hood from the mains supply.
Ensure that:
– it is switched off at the isolator, or
– it is switched off at the wall
socket and the plug removed, or
– the fuse is withdrawn from the
fused spur connection unit, or
– the mains fuse is withdrawn, or
– the screw-out fuse is removed
(in countries where this is
applicable).
^ Remove the grease filter.
^ Remove the charcoal filters if the
cooker hood is being used in
recirculation mode.
Exercise caution when changing
halogen lamps. They get very hot
during use, and remain hot for some
time after being switched off.
Do not touch the surface directly
when changing a lamp, as grease
particles from your fingers will
adhere to the surface and damage
it. Please follow the manufacturer's
instructions.
24
^ Push down the lighting unit slightly
via the opening in the safety panel.
^ The halogen lamp is now accessible
and should be unscrewed
anti-clockwise.
^ Replace it with a new halogen lamp
(specification: GU/GZ 10, 230 V,
50 W). Screw the lamp into the
socket and push it upwards.
We recommend only using lamps of the
same specification and also made by
the same manufacturer as the ones
being replaced.
^ Replace the grease filter and, if being
used in recirculation mode, the
charcoal filters.