Miller FieldPro Remote Instrukcja obsługi - Strona 4

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla System spawania Miller FieldPro Remote. Miller FieldPro Remote 8 stron.

5.
Remote Interface Controls
3
4
6.
Remote Interface Operation Description
AMPS Display
TIG Process Select Button
Stick Process Select
Button
Stick Electrode Type
Select Button
Adjustable DIG and
Hotstart
Amperage Adjustment
Buttons
14-Pin Remote Connected
Indicator
FieldPro ACCESSORY
Connected Indicator
IN USE Button
IN USE Indicator
OM-257 886 Page 4
11
10
5
This display illuminates and shows amperage for either TIG or stick welding process. Measured amperage just
prior to the end of a welding operation will appear on the display for ten seconds after welding operation.
Press and release this button to activate the TIG welding process controls. The TIG text below the button illu-
minates. Adjust the amperage to the appropriate setting within a range from 10 to 350 amps. If the TIG process
has been selected and a remote current/contactor control is connected, holding the TIG process select button
for more than two seconds will display the effective amperage command (based on the amperage setting and
the remote current/contactor control setting).
Press and release this button to activate the stick welding process controls. The STICK text below the button
illuminates as well as the active stick electrode type text. Select the desired stick electrode type and adjust the
amperage to the appropriate setting within a range from 40 to 350 amps.
Press and release button to select the desired stick electrode type (EXX10 or EXX18). The text above or below
the button will illuminate for the active electrode type. This button is only active with the stick welding process
and only then will text for the electrode type illuminate.
.
There may be a "clunk" sound from the power source when switching between Stick and TIG
processes. This is part of normal power source operation.
Press and hold the STICK button for a few seconds to enter adjustable DIG. The right decimal point will
illuminate on the display to indicate DIG. Once in adjustable DIG, press and release the STICK button again
to enter adjustable Hotstart. The middle decimal point will illuminate on the display to indicate Hotstart.
Pressing and releasing the STICK button a third time will exit the menu. The menu will automatically exit
after 10 seconds of inactivity. Pressing and releasing any button other than the STICK button while in the
menu will also exit the menu.
Use these buttons to set the desired amperage setting for either TIG or stick welding process.
The 14-PIN REMOTE text will illuminate when there is a 14-pin accessory connected to the Remote 14 recept-
acle on the power source.
The FieldPro ACCESSORY text will illuminate when there is a FieldPro accessory connected to and properly
communicating with the power source.
Press and release this button on the power source or FieldPro Remote to illuminate the IN USE text. Press and
release again to turn IN USE text off. This lets others know that the machine is being used.
Light automatically turns on when arc is struck. Toggle light using the IN USE button during use. Light will auto-
matically turn off after four hours of inactivity.
1
2
7
8
9
6
.
The FieldPro Remote can only
be used with FieldPro power
sources. See welding power
source Owner's Manual for
additional
information
safety, installation, operation,
and troubleshooting.
1
AMPS Display
2
TIG Process Select Button
3
Stick Process Select Button
4
Stick Electrode Type Select
Button
5
Amperage Adjustment
Buttons
6
14-Pin Remote Connected
Indicator
7
FieldPro Accessory
Connected Indicator
8
IN USE Button
9
IN USE Indicator
10 Check Polarity Indicator
11 Stick Negative Indicator
Ref. 255 429-B / 255 911-A
on