SECTION 7 − MAINTENANCE & TROUBLESHOOTING

7-1. Routine Maintenance

n = Check
* To be done by Factory Authorized Service Agent
Each
Use
n Gas/Air Pressure
Every
Week
n Shield Cup Shutdown
System
l Damaged Or Unreadable
Every
Labels
3
Months
n l Torch Body, Cable
Every
OR
6
Months
~ Inside Unit

7-2. Overload Protection

.
A complete Parts List is available at www.MillerWelds.com
Z = Change
~ = Clean
n Torch Tip, Electrode,
And Shield Cup
~ Air Filter/Regulator
!
Disconnect power
before maintaining.
l = Replace
l Cracked Parts
n l Gas/Air Hose
1
.
Maintain more often
during severe conditions.
Reference
Section 5-2,
7-6
Section 7-4
Section 7-5,
9
1
Supplementary Protector CB1
CB1 protects unit from overload. If
CB1 opens, unit shuts down.
Reset supplementary protector.
Ref. 251 808-A