1.
Measure the Length, Width, & Height (in ft.) of steam shower
or tub/shower being used. Multiply the Length x Width x Height
to get the B asic R oom Volume in CUB IC FEET
L _______ x W _______ x H _______ =
Add to the room volume (a) for each of the following design features
2.
that describe the steambath enclosure:
For natural stones: natural marble,stone
shale, glass block or concrete
For ceramic or porcelain tile on cement board or mortar bed
For each exterior wall or extra glass panel
For each foot exceeding 8ft. in height
3.
Add all figures above to obtain the Total Room Volume required
Compare the Total Cubic Feet required (
IMPORTANT: The guideline for
selecting the steambath generator is a
recommendation only. B ecause of vari-
ables in construction, these sizing
instructions and specifications should be
considered as guidelines only.
Aquasteam will review the model
selected provided we receive complete
information, including working drawings,
specifications, and pertinent electrical
and construction details. Otherwise the
manufacturer disclaims responsibility for
the sizing of a model selected.
Note: To convert cubic feet ot cubic meters, divide cubic feet by 35.3.
E xample: Total cubic feet required is 155. Divide by 35.3 to obtain 4.39 m3. S elect model ABSC02787
2
Residential Steambath Generator Systems
aquasteam
Model
h
) to the Specification Chart below and select the appropriate model.
Selection Chart
Model No.
ABSC02787
ABSC02789
ABSC02782
a
Add 100%
Add 30%
Add 30%
Add 15% per foot
h
Maximum R oom
K W
Vol. ft
3
(cu.meters)
7.5
151-225 (4.27-6.37)
9
226-360 (6.39-10.19)
12
476-575 (13.4-16.28)
aquabrass.com