AQUASTREAM ABSC02789 Instrukcja instalacji, obsługi i konserwacji - Strona 6

Przeglądaj online lub pobierz pdf Instrukcja instalacji, obsługi i konserwacji dla Falownik AQUASTREAM ABSC02789. AQUASTREAM ABSC02789 20 stron.

L oc a t i n g t h e St e a m Ge n e r a t or U n i t
Select a location as near as practical and outside the steam room. Typical locations include: closet, vanity
cabinet, heated attic or basement.
1. Locate steambath generator within 25 feet (7.6 m) of steam room.
2. Do not install steambath generator inside steam room.
3. Do not install steambath generator outdoors or wherever environmental conditions may affect the safety
and/or performance of the generator.
4. Do not install steambath generator or plumbing lines in unheated attic or any locations where water
could freeze.
5. Do not install steambath generator near flammable or corrosive materials or chemicals such as gasoline,
paint thinners, or the like. Installation in areas having high concentrations of chlorine (such as pool
equipment room) must be avoided.
6. Install steambath generator on a solid and level surface. Keyhole slots are provided on for wall mounting.
Insure the steam generator is properly secured and level when mounting with keyhole slots.
7. Install steambath generator in an upright position only.
8. Install anti-water hammer device as necessary.
9. Provide a minimum of 12 inches (30cm) at both ends and top of the steam generator or as required for
servicing. See page 6.
10. Provide unions as required to facilitate installation and disconnection of piping.
11.
I MPORTA N T :
operation and remain hot after shutdown for a period of time. Provide appropriate protection, including
insulating plumbing lines. Avoid plumbing runs and steamhead locations that can come in contact with
bathers, wiring and control cables.
aquasteam
12.
controls can be located inside or outside of the steam room The temperature sensor must
always be placed in the steamroom.
!
w a r n i n g
Aquasteam steam generators are for residential use only . Commercial or other non-residential
applications void the warranty and may adversely affect product performance. Use only aquasteam
series controls.
Ty pi c a I a q u a ste a m i n st a l l a ti o n
For illustrative purposes only.
N o t e :
Consult with qualified designer, architect or
contractor for steam room construction details.
Field installed
power supply
Steam Generator
Provideunions asrequired to facilitate
installtion and disconnect of piping
4
Steam line, safety valve, drain valve, plumbing and steamheads become hot during
Control Cable
Field
installed
water
supply pipe
Field
Valve is
installed
shown open
steam
supply pipe
Re s i de n t i a l St e a m ba t h Ge n e r a t or Sy s t e m s
Steam Head
(shown with available acrylic shield)
In-Shower
Control
Temperature s
IMPORTANT: See pg. 5 & pg.11
for steam head and temperature
sensor location information.
aquabrass.com