Aquatec Equipment AQUAPRO AP2400F Instrukcja obsługi - Strona 4

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Pompy do oczek wodnych Aquatec Equipment AQUAPRO AP2400F. Aquatec Equipment AQUAPRO AP2400F 5 stron. Pond & fountain pump

TROUBLESHOOTING

Problem
Reason
Water Pump Not
No Power
Working
Sponges and filter media
blocked with sludge
Impellor is blocked with
sludge or limescale
Running without sufficient water
Blocked Impellor chamber or ceramic
shaft is broken
Water Pump is noisy
Blockage in pump
Impellor & Shaft worn out
Impellor broken
Water valve closed on the outlet
Unit inlet is blocked or the water
pump inlet is blocked

SPARE PARTS

(NOTE: THESE ARE THE MOST USED)
Description
AQUAPRO AP1000F – V.2015 - Impellor & Shaft
AQUAPRO AP2400F – V.2015 - Impellor & Shaft
AQUAPRO AP1000F – V.2015 – Internal Sponge Filter
AQUAPRO AP2400F – V.2015 – Internal Sponge Filter
AQUAPRO AP1000F – V.2015 - Complete Fountain Kit
AQUAPRO AP2400F – V.2015 - Complete Fountain Kit
A Q U A T E C E Q U I P M E N T . C O M
AQP AP1000F_AP2400F Instructions.indd 6-7
Solution
Check that the plug is connected
and turned on
Clean the sponges and filters
Clean the Impellor as per
the instructions
Submerse the equipment underwater
then plug in. Refill if necessary.
Clean the Impellor. Check for ware.
Replace if necessary.
Clear the blockage
Replace Impellor & Shaft
Replace Impellor
Open the valve and allow
water to flow
Clear all blockages
Product Code
11AI041
11AI042
11AI174
11AI175
11AQ411
11AQ411
AP1000F & AP2400F
POND & FOUNTAIN PUMP
NOTES
A Q U A T E C E Q U I P M E N T . C O M
23/10/2015 7:17 AM