TECHNICAL SPECIFICATIONS
Description
MAXIMUM WATER FLOW (L/H)
MAXIMUM HEAD (m)
POWER CONSUMPTION* (W)
VOLTS (V)
IP RATING
FREQUENCY (Hz)
INLET Ø BSP FEMALE THREAD
OUTLET Ø BSP FEMALE THREAD
CABLE LENGTH (m)
* SUBJECT TO VARIATION ACCORDING TO LOAD.
BENEFITS
The AQUAPRO Fountain and Pond Pump have been manufactured with advanced technology to provide you with the
best quality pump for your pond or water feature. Check out the AQUAPRO range of pond lights and accessories.
• AQUAPRO Fountain & Pond pumps are suitable for use
in many different applications including fountains and
water features, either submersible or inline.
• AQUAPRO Fountain & Pond pumps are a magnetically
driven centrifugal pump, therefore they cannot suck
from a water level that is below the inlet level when
used inline.
• Your AQUAPRO Fountain & Pond pump has a single
moving part (an impellor set) enabling easy cleaning
and maintenance.
• The motor and electrical components are encapsulated
in epoxy resin, ensuring safe operation under water.
A Q U A T E C E Q U I P M E N T . C O M
AQP AP1000F_AP2400F Instructions.indd 2-3
AP1000F
AP2400F
1200
2600
2.00
2.80
36
92
240
240
IP68
IP68
50
50
½ INCH
1 INCH
½ INCH
½ INCH
10
10
• The pump has a robust bearing and shaft design so no
oil/grease lubrication is required.
• AQUAPRO pumps that have plastic impellor parts and
ceramic shafts, with no exposed metal, can be used in
salt water applications.
• AQUAPRO fountain pumps are fitted with suction
cup feet, enabling use on both horizontal and vertical
surfaces.
• AQUAPRO Fountain & Pond Pumps are continuous
rated therefore are designed to operate 24/7.
AP1000F & AP2400F
POND & FOUNTAIN PUMP
IMPORTANT SAFEGUARDS
Please read the operating instructions and familiarise yourself with the equipment before placing it
in service. Correct and safe use of the system requires strict compliance with the safety instructions.
For safety reasons, persons less than 16 years of age or infirm persons that are not familiar with these
instructions should not use this equipment.
• For your own safety, disconnect from the power supply
before any maintenance of any equipment is attempted
on the tank or water body.
• Be sure the equipment is submerged completely in the
water. The depth should not be greater than 2m.
• Do not operate the pump if the appliance or any
components of the system, such as the power cable,
have been damaged.
• Always use a properly grounded power supply that is
connected to an RCD with a rated residual operating
current not exceeding 30mA. As per AS/NZS
3350.2.41:1997
• The drip loop method should be used to prevent water
from traveling down the cable and onto the plug or
power supply. If the plug does get wet, do not unplug
the cable. Disconnect the circuit breaker that supplies
power to the power supply point. Then unplug and
examine the plug and power supply point for presence
of water. If the power point has become wet, you should
consult an electrician before using the power point
again.
• Always unplug the pump from the power supply when
not in use or before performing any maintenance on the
pump or in the pond. Never pull the cable to disconnect
the plug from the power supply. Grasp the plug and pull
to disconnect.
PRODUCT SPECIFIC SAFEGUARDS
• Do not operate the pump without water at any time, permanent damage may occur.
• Be sure the equipment is submerged completely in the water. The depth should not be greater than 2m.
• Do not operate the pump if the appliance or any components of the system, such as the power cable, have been
damaged.
• The pump is designed to be used in a Garden pond or Aquarium environment. It is not to be used in any other manner
or purpose.
• The pump should only be used in clean water. Do not use the pump in, or with, any chemicals such as a solvent or
gasoline.
• All AQUAPRO Fountain & Pond pumps are water cooled. If the pump flow becomes restricted it will overheat and
could cause permanent damage. The pump needs to be cleaned regularly to prevent the pump becoming blocked,
thus causing the pump to overheat and burn out. This is not a warrantable event.
A Q U A T E C E Q U I P M E N T . C O M
• Use of extension cords outdoors is not recommended.
• If required, have a qualified electrician install a
weatherproof power supply point near to the pond or
water-feature (within the cable length of the appliance).
• Do not install or store the appliance where it will be
exposed to extreme hot or cold temperatures. Do not
use in water above 35°C.
• Do not cut the cable as this will result in voiding your
warranty.
• Care should be taken to arrange the power cable so
that it cannot be accidentally tripped over or pulled.
• Do not attempt to repair the electrical appliance
yourself. Return to an authorized service centre or place
of purchase if a fault occurs, (regular maintenance is not
considered repair and is required by user).
• The power cord cannot be replaced. If the cord is
damaged, the pump must be discarded.