Siemens SITRANS WW310 Instrukcja obsługi - Strona 31

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Urządzenia przemysłowe Siemens SITRANS WW310. Siemens SITRANS WW310 48 stron. Weighfeeders

Siemens SITRANS WW310 Instrukcja obsługi
Note
Load cell may appear different than shown.
Step 3
Support the scale idler/deck from below or above, and remove the two top/front load cell mount
bolts. Be careful not to move the idler as it is still attached to the load cell on the other side of the
weighfeeder.
Step 4
Remove the two bottom load cell mount bolts.
Step 5
Remove the load cell off the feeder.
SITRANS WW310
Operating Instructions, 03/2014, A5E33490433-AA
Load cell
Bottom load cell mount
Shipping screw
8.7 Load cell replacement
Overload screw
Top/front load cell mount
Start Up