Siemens SITRANS WW310 Instrukcja obsługi - Strona 32
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Urządzenia przemysłowe Siemens SITRANS WW310. Siemens SITRANS WW310 48 stron. Weighfeeders

Start Up
8.7 Load cell replacement
8.7.2
Installing new load cell
Step 1
Slide the new load cell into position.
Step 2
Install the two bottom load cell mount bolts and tighten them by hand.
The load cell should now be resting against the overload stop.
Step 3
Install the two top/front load cell mount bolts. Tighten them by hand.
Step 4
Start with the bottom load cell mounting bolts, and tighten them to the torque rating specified
with the new load cell. Now tighten the two top/front load cell mounting bolts to the same torque
value.
Step 5
Route the load cell cable to the junction box, and connect the load cell according to the supplied
interwiring diagram.
Repeat for other load cells if necessary
Step 6
Perform a load cell balancing procedure as described in the integrator instruction manual.
30
Operating Instructions, 03/2014, A5E33490433-AA
SITRANS WW310