Cable Electronics CE Labs SW808HD Instrukcja obsługi - Strona 10

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Przełącznik matrycowy Cable Electronics CE Labs SW808HD. Cable Electronics CE Labs SW808HD 17 stron. High definition matrix switch

RS-485 COMMUNICATION PORT CONNECTION
METHODS
The RS-485 port will control more than one product. The RS-485 Port
is shown below.
RS-232
ID
RS-485 Terminal
RS-485
A. DIP switch 8:(RS-232/RS-485 on/off)
• ON:RS-232 enables single system or RS-485 serial master
• OFF:RS-485 enables RS-485 serial slave B.
B. DIP switches 6 and 7 (RS-485 - terminator on/off)
• ON enables Terminator
• OFF disables Terminator
C. DIP switches 1 to 5 (ID address setting)
The ID address determines the position of a matrix within a system.
When multiple Matrix units are connected to one PC or when the
Matrix units are serially connected, the ID address decides which
Matrix is controlled. The chart below describes the ID addresses.
ID ADDRESS SETTINGS
Software ID
ON/OFF
ID Address
Address
(Binary)
(Decimal)
(Hexadecimal )
0
00
00000
1
01
00001
2
02
00010
3
03
00011
4
04
00100
5
05
00101
6
06
00110
7
07
00111
8
08
01000
RS-485
TX
RX
ON/OFF Switch Settings
SW1
SW2
SW3
SW4
SW5
off
off
off
off
off
off
off
off
off
on
off
off
off
on
off
off
off
off
on
on
off
off
on
off
off
off
off
on
off
on
off
off
on
on
off
off
off
on
on
on
off
on
off
off
off
DISCONNECT ALL: COMMAND FUNCTION
DESCRIPTION
Use this command to close all the switching paths at one time. Press
the Disconnect all key to close connection to all input and output ports.

MEMORY FUNCTION USAGE

Store and Retrieve Function Description
The Store Function saves all the present input/output switching relations
to any Locations from #1 to #8 desired. The Retrieve Function is used to
retrieve these saved input/output switching relations.
Store Function Example
Store all the present input/output switching relations to Location #1;
1. Select Location #1 as shown in the figure above,
2. Click the Save key to save all the present input/output switching
relations to Location #1.
Retrieve Function Example
To retrieve the input/output corresponding relations saved in Location #1;
1. Select Location #1 as shown in the figure below
2. Click the Load key to retrieve all the input/output corresponding
relations stored in Location #1.
Scan Function Usage
Use the mouse to click the Scan key to refresh the AV Matrix operating
interface.
Options Function Usage
This is an Activation Function for connecting a PC to a Matrix set.
1. In the main menu, select Options
to pop up the Options window.
2. In Port Number field, select either
COM1 port or COM2 port.
3. In BAUD Rate select 9600 for
signal transmission
4. Select OK to finish.9600