Digitrax DS74 Podręcznik - Strona 6

Przeglądaj online lub pobierz pdf Podręcznik dla Jednostka sterująca Digitrax DS74. Digitrax DS74 8 stron. Complete train control

Digitrax DS74 Podręcznik
6.0 Advanced DT602 based DS74 configuration
To perform these advanced features, the DT602 will need to be user updated to
SubVersion 5.0 or higher, or a July 2021 or later IPL - see www.digitrax.com.
6.1 Detecting all DS74's and setting Base addresses:
updated DT602 plugged into LocoNet, press the; Menu>3>4 keys to enter the
Route Editor menu. If any DS74 is plugged into LocoNet, the DT602 will beep
after about one second and show "DS7x" routes at the D soft key position.
1.
Press the D soft key to now enter the "Selecting DS7x device " screen as
shown below. This example DT602 screen shows four DS74 devices detect-
ed, their Base switch (SW) address, active switch address range# and unique
device serial numbers (SN or SerNo).
The lowest DS74 Base address detected and sorted is SW0001, with 4
2.
outputs with SN 9122. This is displayed in GREEN to indicate that it does
NOT conflict with the second DS74 SN 3122 at Base address 5. This is true
because the next free address is SW1+4 or SW0005, that second DS74 SN
3122 is set at or above. You can use the LH encoder knob to scroll up and
down through the detected DS74 lines, with an underline showing the
selected DS74.
3.
The third DS74 shown at Base SW9 has
8# outputs shown, so it is configured by
OPSW's to operate 8 on/off light outputs
instead of 4 T/C turnout controls.
4.
The 4th DS74 at Base Sw10 overlaps the
third DS74, and so is displayed in RED
text, because SW9+8 would require the
4th DS74 SN9945 to have a base address
of at least Sw17 to avoid SW# overlaps.
5.
Rotate the DT602 LH encoder knob to
underline the fourth DS74 line entry.
6.
Press the numbers 1 then 7 then press
the A soft key "Chng Adr". The last DS74
will change to Base SW17 and now show
GREEN because there are now no SW
overlaps of any DS74's detected.
7.
To identify the actual underlined fourth
physical DS74 on the layout; press the
F soft key "Ident" and just this DS74 will blink its ID/OPS/RTS leds for 3
seconds. Press "X" to exit any DT602 advanced mode.
8.
This advanced DT602 capability allows you configure all DS74's in position
on a LocoNet layout, quickly and conveniently, even if all devices are initially
at factory-default Base SW1.
9.
If you are using other types of Switch control decoders, you will have to note
their active SW addresses and manually ensure the DS74's are configured to
avoid these.
© 2021 Digitrax, Inc.
CsRt
Selecting DS7x device
Device:
DS74
DS74
DS74
DS74
DS7x device select: LH knob
Chng adr
— 6 —
Ident
Base+Out#
SerNo
Sw0001+04# 9122
Sw0005+04# 3122
Sw0009+08# 2500
Sw0010+04# 9945
www.digitrax.com
On an