Installing the SIMM
When inserting SIMMs, use firm but not excessive pressure. If you damage a socket, you
Note
will have to return the RSP4+ to the factory for repair.
Gently push the SIMM into the socket until the spring clips snap over the ends of the SIMM. If
Step 5
necessary, rock the SIMM gently back and forth to seat it properly. (See Figure 7.)
Figure 7
3.
The socket guide posts insert
through the SIMM holes
(on both sides).
4.
The locking spring will
clip the back of the SIMM
when it is fully installed
(on both sides).
3.
The socket guide posts insert
through the SIMM holes
(on both sides).
4.
The locking spring will
clip the back of the SIMM
when it is fully installed
(on both sides).
Step 6
Confirm that the SIMM is properly seated. If the SIMM is properly seated, the socket guide posts
should insert through the alignment holes, and the connector springs should click into place. If the
SIMM appears misaligned, carefully remove it and reseat it in the socket. Push the SIMM firmly back
into the socket until the spring clips snap into place.
This completes the new SIMM installation procedure.
RSP4+ Bootflash Memory Upgrade to 16MB Installation and Configuration Guide
14
Inserting Vertically-Loaded SIMMS
Front of the chassis
1. Insert the SIMM into the socket at an angle 45 from vertical.
2. Push the SIMM down and back.
Side view
1. Insert the SIMM into the socket at an angle 45 from vertical.
2. Push the SIMM down and back.
Top view
Polarization
notch
78-12288-02