Open (OPN) input & OPN push button
The OPN inputs are Push Button OPN and Terminal OPN input. Push OPN button or Activating
(connect OPN terminal to the COM (+12V)) the OPN input will start the gate to open. When gate
opened, if OPN is still activating, the gate will stay open.
Pedestrian Access (PED) input and Pedestrian (PED) push button
The pedestrian input partly opens gate.
CLS push button
The CLS push button on control board is to close gate.
OSC (open/stop/close) input and OSC push button
OSC input and OSC push button is for manual operation. Push to open the gate, push again stop gate,
another push close the gate. When gate stopped by OSC input, auto close mode does not apply.
Photoelectric safety beam (PE) input
If the P.E input activated while gate is closing, the gate will stop or reopen depending on the DIP
setting. If the gate in the opened position and P.E beam activated, the gate will stay in opened.
Encoder inputs
Encoder in mounted on the motor shaft. There is not service is required. 4 pins socket from encoder
directly plug in on the control board. Two plugs on the control board are for right hand or left hand gate.
Drive signals (between control board and inverter)
Plug 1 link inverter and control board. This is five pins plug. Two pins for 12VDC supply from inverter
to control board and other three pins is from control board to inverter, open, close and running
frequency signals.
Lock output signal
Lock output relay has COM, N/C, N/O outputs. The output can be pause or presence set by DIP3.
Gate close (status) output signal
When gate in closed position the relay contact is on, this used to send closing signals to alarm system.
As long as the gate is not closed, the relay contact will be off and tell the alarm system, the gate is open.
4. DIP SWICTH FUNCTION
SET/RUN (DIP1)
Dip1 ON selects setting mode.
Slave/Master (DIP2)
This is for two motors (reserved for late use)
LOCK Output (DIP3)
DIP3 ON selects lock output is pulse at every start cycle. DIP3 OFF selects lock output is presence.
The lock relay will be on if the gate is in opening and closing cycle. All other situations will be off.
Security close (DIP4)
DIP4 ON selects security close mode. In this mode, while the gate is opening, if the PE beams trigged
and clear, the gate stops and begins to close; even it is not fully open. While the gate is closing, if the
PE trigged, the gate will stop (not reopen) until the PE beams is clear, then gate continues to close.
DIP4 OFF no this function. DIP4 is prior to DIP5
PE trig close (DIP5)
beam trig auto close mode. In this mode, if P.E beams trigged and clear the gate will auto close after
gate opened. If the P.E beams trig again, the gate will reopen as long as the P.E input active,
DIGIWAY PTY LTD
CONTROL INPUIT AND BUTTON
ON=SET,
ON=SLAVE
ON= PLUSE
ON=SEC CLS
ON=PE CLS
5
OFF=RUN
OFF= MASTER
OFF= PRESENCE
OFF=NO SEC CLS
OFF=NO PE CLSDIP5 ON selects PE