until gate is fully opened. If the PE is clear, the gate will open another 2 seconds, then gate will close
again after PE close delay time. DIP5 OFF no this function. DIP5 is prior to DIP6.
Auto CLS (DIP6)
DIP6 ON selects Auto close mode. I this mode, the gate will auto close after standard auto closed time.
If DIP6 OFF, no this function.
5. Timer Settings
Push Buttons functions
Button
Dip1 on---STD Setting
OPN
Open Length Set
PED
Auto close time set
CLS
Manual close gate
OSC
Lock pulse time set
5.1 STD(standard) time setting mode
To get into standard setting mode, just set DIP1 to on. Following settings can be set in standard setting
model
Gate length set up -- Limit switch set up
a) Connect 240V AC (if not done) and make sure power is off.
b) Releases clutch and push gate to middle position, and then engage the clutch.
c) Make sure no signals connect to OPN, PED, OSC and PEB terminals. Set DIP6 on.
d) Turn power on, gate should start close at low speed. If not, turn power off, change motor direction
by swapping any two of three phases (from motor side)
e) Power on again. Gate should start to close. Look at RED LED should be flash and GREEN LED
is off. If not, turn power off, change encode plug to other connector.
f) Power on again, gate start close, RED LED is flash and GREEN LED is off. When gate hit the
closed stopper, gate will stop. For P550 the gate will open a little bit, do not move the gate, just
go to next step.
g) Set DIP1 on. Push and hold OPN button, gate will start open at low speed. When gate reach
opened position, (about 50mm away opened stopper). Just simply release the OPN button.
Controller will save the current position as fully opened position. While hold OPN button, push
and release PED button will save current gate position as PED opened position.
h) Set DIP1 off and push CLS button, gate will start to close. When gate fully closed, gate will be
ready to operate. Then try to open and close. If not satisfied with the position, just repeat step (g)
to (h).
Auto close time set
Push and hold on PED for the auto close time setting. Now the red and green LED flash fast
alternatively, When reached the required time simply release PED button. Set DIP1 OFF. The gate
controller will back to working mode.
Lock pulse time set
Push and hold on OSC for the lock pulse time setting. Now the red and green LED flash fast
alternatively, and when gate reached the required time, simply release OSC button. Set DIP1 OFF.
The gate controller will back to working mode.
5.2 SPE(special) time setting mode
To get into special setting mode, turn power off, set DIP1 on. Push and hold CLS button then turn
power on, LED will be on for short time, after LED off simply release CLS button. Gate controller is
getting into special time setting mode.
DIGIWAY PTY LTD
CONTROL BOARD SETTING
ON=AUTO CLS
SPE Setting
Sync delay time
Motor stop time set
PE close time set
Reserved
6
OFF=NO AUTO CLS
Dip1 off---Running
Full open
Pedestrian open
Close
OSC