Dillon ED-2000plus Podręcznik użytkownika - Strona 13

Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Przyrządy pomiarowe Dillon ED-2000plus. Dillon ED-2000plus 20 stron. Electronic dynamometer with hr-2000 remote

Operation

Key
ON/OFF
F + ON/OFF
(while unit is off)
F+ ON/OFF
(while unit is on)
PEAK HOLD
TEST
F + PEAK/HOLD
F + TEST
F + ON/OFF
ON/OFF
ALT + ON (while unit is off)
F + ALT
UNITS

Powering Up

For Radio Communication

While operating the HR-2000,
the lower part of the leftmost
digit may be observed to flash.
This occurs when the HR-2000
wants to transmit a message
and is waiting for access or for
an answer. Operating under
good radio conditions, this will
be rarely seen.
The key functions for the HR-2000 are listed in Table 6.
Function
Turns the unit on in radio mode. RS-485 wireline communi-
cation will also function.
Press these two keys to power up the unit in RS-485
wireline mode. This disables radio function and preserves
battery life.
Puts the unit into addressing mode and shows the address
that is to be polled.
Increments the address by 1 count.
Decrements the address by 1 count
Increments the address by 10
Decrements the address by 10
Returns unit to normal display mode.
Turns the unit off
Forces unit into RS-232 mode
Places remote in LISTEN mode. The remote waits for a poll
signal from the attached peripheral, requests the reading
from the ED-2000plus and returns the reading to the periph-
eral.
Press this to save changes and move to the next item.
Hold the UNITS key to see the item name, release it to see
the value.
Table 6
Key Functions for HR-2000
To power up for use with the radio link, press the ON/OFF key on the
ED-2000plus then the press the ON/OFF key on the HR-2000.
When you turn on the HR-2000 for radio use, the display will show the
software revision number (probably hr2001), then the word rAdio. Until the
corresponding ED-2000plus is powered up and communicating with the
HR-2000, the letter r will flash back and forth between inverted and upright.
When communication is established and working properly the display will
mirror the ED-2000plus display and the leftmost decimal point will blink every
½ second. If communication is broken, the display will flash a small o in the
lower left corner of the display. If communications are not resumed within ten
seconds, the display will show rAdio and the letter r will flash back and forth
between inverted and upright.
Display
rAdio
rS-485
SEtuP-100
101
99
110
90
-donE-
OFF
-duAL-
LiStEn
See Table 7
headings
13