3Com WL-306 Instrukcje dotyczące testu - Strona 4
Przeglądaj online lub pobierz pdf Instrukcje dotyczące testu dla Bezprzewodowy punkt dostępowy 3Com WL-306. 3Com WL-306 4 stron.
>tc
Set up the Receive PC as below then send the packets.
>t 10000
{Transmitting 10000 packets. This takes approximately 75 seconds. To
transmit for more time simply increase the number of frames}.
>T
{Starts Transmitting the packets. If you cannot see them being received on
the PC Card then ensure that the channel is set identical to above and that
the card is set to receive (r 0)}
Receive PC using PC Card WL-305 (Use PC Card set up in PC RA&A74)
These 10000 packets can be viewed on the Receive PC set up as follows.
Insert the WL-305 PC Card
Click on the WL-306 icon
At the DOS prompt enter the following command:
C:\speedracer poldebug 6.
{You should now be at the debugging prompt for the WL-305. Please then enter the
following commands to show the received data}
>c 1
{To select the same channel as the send}
>r 1
{To enable display on the receive}
You will then see:
"Good frame......." Being displayed on the receive as each packet is received.
>RXSTATS {Type this to display information on the received packets. It will show
Total number of packets received, good packets and packets with CRC
errors.
NOTE: There is a bug in the program which always shows 7 CRC errors. This is the
same whether you send 10000 or 20 frames}