Ariston 200D Instrukcje instalacji, użytkowania i konserwacji - Strona 5

Przeglądaj online lub pobierz pdf Instrukcje instalacji, użytkowania i konserwacji dla Podgrzewacz wody Ariston 200D. Ariston 200D 33 stron. Heat pump water heater

PRODUCT DESCRIPTION

The floor-standing heat pump water heater consists of a top block
containing the heat pump unit and the bottom part of the with the
storage tank. There is a control panel with a display on the front
part.
Dimensions
OUT
IN
F
B
L
I
M
A
371
600
A
Inlet cold water ¾" connection
B
Outlet hot water ¾" connection
C
Condensate drain connection with 14mm diameter
D
Auxiliary circuit ¾" inlet pipe (SYS and TWIN)
E
Auxiliary circuit ¾" outlet pipe (SYS and TWIN)
F
Sheath for upper probe (S3) (SYS and TWIN)
G
Auxiliary circuit ¾" inlet pipe (TWIN SYS)
H
Auxiliary circuit ¾" outlet pipe (TWIN SYS)
I
Sheath for upper probe (S4) (TWIN SYS)
L
Recirculation ¾" pipe (SYS and TWIN SYS)
M
Sheath for bottom probe (S2) (SYS and TWIN SYS)
N
Display
O
Touch buttons.
OUT
IN
C
F
B
G
L
H
I
D
A
E
N
MODE
MENU
SET
O
Main components
17
1
2
3
4
5
6
7
8
1
Fan
2
Hot gas valve
3
Safety pressure switch
4
Electronic expansion valve
5
Evaporator inlet NTC temperature probe
6
Electronic box
7
Bottom NTC temperature probe (heating element zone)
8
Electric heating element
9
Top NTC temperature probe (hot water)
10
Hermetic rotary compressor
11
Condensate drain pipe
12
Lateral connections
13
Low pressure outlet
14
Air NTC temperature probe
15
Compressor suction NTC temperature probe
16
Evaporator filter
17
Evaporator
16
15
14
13
12
11
10
9
5 / EN