Ariston 200D Instrukcje instalacji, użytkowania i konserwacji - Strona 7

Przeglądaj online lub pobierz pdf Instrukcje instalacji, użytkowania i konserwacji dla Podgrzewacz wody Ariston 200D. Ariston 200D 33 stron. Heat pump water heater

HEATING ELEMENT
Heating element power
Max. water temperature with heating element
Max. current consumption
POWER SUPPLY
Voltage / max. power consumption
Frequency
Protection rating
AIR SIDE
Standard air flow rate (automatic modulating control)
Available static pressure
Minimum volume of room of installation (
Minimum ceiling height of room of installation (
Min. temperature of room of installation
Max. temperature of room of installation
Minimum air temperature (w.b. a 90% u.r.) (
Maximum air temperature (w.b. a 90% u.r.) (
Further energy data is shown in the Product Data Sheet (Annex A) which is an integral part of this booklet. Products that are not provided with a label
and corresponding product fiche for a combination of water heater and solar devices, as specified by Regulation 812/2013, are not intended to be used
for these kind of combinations.
(A) Values obtained with outdoor air temperature of 7°C and relative humidity of 87%, inlet water temperature of 10°C and temperature set at 55°C (as per the provisions in EN 16147).
Ducted product Ø200 mm,
(B) Values obtained with outdoor air temperature of 7°C and relative humidity of 87%, inlet water temperature of 10°C and temperature set at 55°C (as per the provisions of 2014/C 207/03 - transitional
methods of measurement and calculation). Ducted product Ø200 mm.
(C) Values obtained from the average of the results as per the provisions in EN 12102-2. Ducted product Ø200 mm.
(D) Value that guarantees the correct operation and easy maintenance with non-ducted products. The correct operation of the product is nevertheless guaranteed up to a minimum height of 2.090 m.
(E) Beyond the heat pump temperature range of operation, heating of the water is ensured by integration (as per provisions of EN 16147).
D
)
D
)
E
)
E
)
V / W
Check product specification label
°C
A
V / W
Check product specification label
Hz
m³/h
Pa
m
1,940
°C
°C
°C
°C
75
11,48
50
IPX4
650
230
30
2,200
1
42
-10
42
7 / EN