of the type of installation to make.
Caution! In some models the rear hole duct is not easily
accessible, even when the tap (if mounted) is removed, in this
case remove the plastic piece E1 or E2 that is blocking the
hole duct, by unwinding using pliers and cutter. Check that
the filter/suction selector (inside the cooker hood) G is in the
suction (A) position.
Filter version
In the case where it is not possible to discharge the cooking
fumes externally, the cooker hood may be used in the filter
version by fixing a carbon filter, the fumes and vapours are
recycled via the anterior grill placed above the control panel.
Check that the filter/suction selector (inside the cooker
hood) G is in the filter (F) position.
The models with no suction motor only operate in ducting
mode, and must be connected to an external suction device
(not supplied).
The connecting instructions are supplied with the peripheral
suction unit.

Installation

Preparing for installation
WARNING:
this is a heavy product; the hood
should only be lifted and installed by two or more people.
The minimum distance between the supporting surface for the
cooking equipment on the hob and the lowest part of the
range hood must be not less than 60cm from electric cookers
and 75cm from gas or mixed cookers.
If the instructions for installation for the gas hob specify a
greater distance, this must be adhered to.
Electrical connection
The mains power supply must correspond to the rating
indicated on the plate situated inside the hood. If provided with
a plug connect the hood to a socket in compliance with current
regulations and positioned in an accessible area. If it not fitted
with a plug (direct mains connection) or if the plug is not
located in an accessible area apply a double pole switch in
accordance with standards which assures the complete
disconnection of the mains under conditions relating to over-
current category III, in accordance with installation
instructions.
Warning! Before re-connecting the hood circuit to the mains
supply and checking the efficient function, always check that
the mains cable is correctly assembled.
Warning! Power cable replacement must be undertaken by
the authorised service assistance centre or similar qualified
person.
Mounting
Expansion wall plugs are provided to secure the hood to most
types of walls/ceilings. However, a qualified technician must
verify suitability of the materials in accordance with the type of
wall/ceiling. The wall/ceiling must be strong enough to take
the weight of the hood. Do not tile, grout or silicone this
appliance to the wall. Surface mounting only.
The cooker hood may be installed on the wall or on the base
of a cabinet; if supplied, use the hole gauge H to drill the
correct distance, otherwise lean the cooker hood on the wall
or on the base of the cabinet and mark the holes with a pencil.
Wall mounting - Insert the wall screw anchors J in the drilled
holes and the two K screws in the upper drill holes, remove
the grill and hook the cooker hood to the 2 screws, finally from
the inside, insert the third screw L and lock them all in.
Cabinet fixing - Affix the cooker hood with the 4 M screws
from inside the cabinet.

Operation

The hood is fitted with a control panel with aspiration speed
selection control and a light switch to control cooking area
lights.
Use the high suction speed in cases of concentrated kitchen
vapours. It is recommended that the cooker hood suction is
switched on for 5 minutes prior to cooking and to leave in
operation during cooking and for another 15 minutes
approximately after terminating cooking.

Maintenance

WARNING:
-
Use safety gloves.
-
Disconnect the appliance from the power supply.
Or if the appliance has been connected through a plug and
socket, then the plug must be removed from the socket.
Cleaning
WARNING:
-
Never use steam cleaning equipment.
-
Disconnect the appliance from the power supply.
The cooker hood should be cleaned regularly (at least with the
same frequency with which you carry out maintenance of the
fat filters) internally and externally. Clean using the cloth
dampened with neutral liquid detergent. Do not use abrasive
products. DO NOT USE ALCOHOL!
WARNING: Failure to carry out the basic cleaning
recommendations of the cooker hood and replacement of the
filters may cause fire risks.
Therefore, we recommend oserving these instructions.
The manufacturer declines all responsibility for any damage to
the motor or any fire damage linked to inappropriate
maintenance or failure to observe the above safety
recommendations.
Grease filter
Traps cooking grease particles.
If situated inside the support grill, it may be one of the
following types:
Paper filter must be replaced once a month or if colouring
appears on upper side, in such cases the colouring is evident
through the grill openings.
6