CONTROL PANEL
A. Light switch.
B. Speed selector switch.
REPLACING BULBS:
1. Disconnect power.
WARNING: Wear gloves.
2. Remove the grease filter support grille (Fig. 2) or the grease filter
to access the lamp housing (Fig. 1). On some models the lamp
cover can simply be prised off using standard screwdriver
(A - Fig. 1).
3. Remove the burnt-out bulb.
Replace using 40 W max E14 bulbs only.
4. Refit the extractor grille or lighting unit.
WARNING: Disconnect the hood from the mains supply
before carrying out this procedure.
REMOVING AND REPLACING OR CLEANING
THE GREASE FILTER:
Grease filter - it can be one of the following types:
Paper filter: to be replaced once a month or, if the top part is
coloured, when the colour shows through the holes in the grille.
Metal filter: to be washed once a month by hand or in a dishwasher
with quick wash cycle at low temperature.
Note: The metal filter may become opaque over time; this does not
affect its filtering capacity.
1. Disconnect power.
2. Remove the extractor grilles or the grease filters - using parts L or
N, (Fig. 1).
3. Release the grease filter (selected models - Fig. 3).
4. Remove the dirty grease filter.
5. After the grease filter has been replaced or cleaned (depending on
model), refit the parts in reverse order, making sure the entire
extraction surface is covered.
FITTING OR REPLACING THE CARBON FILTER:
Fitting or replacing the carbon filter (filter hoods only):
Change the carbon filter every four months.
It cannot be washed or regenerated.
1. Disconnect power.
2. Remove the extractor grilles or the grease filters (Fig. 1) or the
surround (Fig. 2).
3. Rectangular filter: position the filter A so that it covers the motor
protection grille and turn the knob clockwise. To release,
proceed in reverse order.
Round filter: Insert the carbon filter over the motor protection
grille, on some models the reference mark B must line up with
the arrow C printed on the fan shroud; next, turn clockwise.
4. To remove the filter, turn the filter or knob anti-clockwise.
5. Refit the grille, the filter or the grease filter surround.
-Change the carbon filter every four months.
PRODUCT SHEET
Fig. 2
8
Fig. 1
Fig. 3
Fig. 4