Clark Synthesis TACTILE SOUND TST329 Instrukcja instalacji - Strona 12
Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Przetwornik Clark Synthesis TACTILE SOUND TST329. Clark Synthesis TACTILE SOUND TST329 20 stron. Platinum, gold, silver and all weather transducers
Również dla Clark Synthesis TACTILE SOUND TST329: Arkusz danych (1 strony)
Installation: Wood Decks
Measure the overall dimensions of the deck. For best results, it is recommended that one (1) AW339
1
be installed for every 10 ft. by 10 ft. (3 m by 3 m) section of deck. For example, if you have a deck that
is 10 ft. by 20 ft. (3 m by 6 m), you would need to install two (2) AW339 transducers on that deck.
The transducer should be mounted in a location that is equally spaced from the sides of the deck and
other transducers. As general examples, the diagrams below provide top views of 10 ft. by 10 ft. (3 m
by 3 m) and 10 ft. by 20 ft. (3 m by 6 m) deck surfaces with the transducers mounted equal distances
from each other and from the edges of the deck.
If the deck is a custom shape, approximate the placement of the transducers using the general
recommendation of one transducer for every 100 ft.
10 ft. (3 m)
5 ft.
(1.5 m)
Transducer
When determining the actual mounting location(s), it is important to decide which type of mounting
2
style you want to use. There are two commonly used mounting styles: the joist mount or the bridge
mount. See the diagrams of each style below.
12
Tactile Sound Transducers
5 ft.
(1.5 m)
Joist Mount
Bridge Mount
Arched Bridge
(9 m
).
2
2
20 ft. (6 m)
Transducers
6.7 ft.
6.7 ft.
(2.05 m)
(2.05 m)
Minumum 3/4" (1.9 cm) Thick
Joist
Drill 5/16" (.79 cm) Hole
3/8"- 16 Hanger Bolt
Jam Nut
3" (7.6 cm)
5-1/2" (14 cm)
Jam Nut
Jam Nut
6.7 ft.
(2.05 m)
Tip: Tighten two Jam
Nuts against each other
to screw in the Hanger
Bolt with a wrench.
Straight Bridge