Fitting the Canopy Hood

Before starting to fix the canopy, tighten
the two screws Vr located on the canopy
mouiunting brackets.
-
Hook the canopy onto the screws (not
supplied).
-
Tighten up the screws.
-
Adjust the screws item Vr to level the
canopy.
The fixings come together with the splashback.
Ducting the Cooker Hood
When installing the cooker hood in the ducting
mode, connect the hood using either Ø150 or
120mm flexible or rigid pipe.
The choice of ducting should be specified by the
installer but Ø150mm rigid ducting will ensure the
best performance possible.
The ducting used must be manufactured
from fire retardent material conforming
to the relevant British Standard or DIN
4102-B1.
Fitting the Ducting
-
To install Ø120mm ducting, fit the ducting
spigot Ø150-120mm item 9 on to the
spigot on top of the canopy.
-
To install Ø150mm ducting, fit the ducting
on the spigot on top of the canopy.
-
Remove the activated charcoal filter.
Recirculating the Cooker Hood
The cooker hood is supplied specified for use in
the recirculation mode, with the charcoal filter
already fitted.
Fitting the Recirculation Duct
-
Assemble the two halves of the ducting
extension pipe item 14.
-
Push-fit the extension pipe on to the
ducting spigot on top of the canopy.
-
Push-fit the recirculation adapter item 15
on to extension pipe item 14.
-
Insert the recirculation outlet extensions
item 14.4 into the recirculation adapter
item 15.
-
The recircualtion grilles item 8a and 8b
must be fitted after the lower chimney
item 2.2 has been fitted.

Electrical Connection

Connect the hood to the mains supply via a
double-pole switch having a contact gap of at
least 3mm.
INSTALLING THE COOKER HOOD
ø 150
9
15
8b
14
Vr
ø 120
14.1
8a