For your own safety
1.
An approved Residual Current Device (ROD) must be used when pumping
from ponds or swimming pools.
2.
Your Hippo 2 may only be used for pumping water from a swimming pool
when there is no person or animal in the pool.
3.
Always disconnect the pump from the electrical supply before placing your
Hippo 2 into, or removing it from the water, and before any cleaning or
maintenance of the pump.
Installation and Operation
The Hippo 2 is designed for use with clean fresh water. Avoid using your pump
with salt water, or with water containing chemicals, as these can cause damage
to the pump. If the pump does come into contact with salt water or chemicals,
wash it in fresh water immediately.
Always use the moulded handle, with a rope or cord attached if necessary,
when lifting the pump. Do not lift the pump by the mains or float switch cables.
Do not use the pump if the water is liable to freeze, as this can cause damage to
the pump. Remove the pump from the water and store it in a frost free location.
If the Hippo 2 is to be used where there may be silt or mud (for example, garden
ponds), keep the pump clear of any sediment by standing it on a platform or brick.
Inspect the pump regularly to check that the base inlet is clear of leaves or other
debris. Any blockage of mud or leaves can be cleared by washing the pump in
fresh water, or by using a garden hose to flush fresh water back through the
pump outlet connector. Never switch on the pump with the outlet connected to
the mains water supply. The mud pack (item 2) and screen/filter (item 6) can be
removed for cleaning if necessary. Remove the mud pack (3 screws around the
base), followed by the screen/filter (3 more screws) if necessary.
Maintenance
This pump should require no maintenance other than
regular cleaning. If the pump starts to show signs of wear
or damage contact our Service Department for advice.
Do not use the pump if there is any damage to the mains
supply cable. Do not attempt to repair the pump yourself
(other than to replace those parts listed below), as you
may invalidate your guarantee, and damage the
waterproof seal of the pump.
To fit a new mains lead, remove the two screws and the
retaining plate from around the mains lead connector
plug, and pull the plug from its socket. When replacing,
the plug must be sealed using a clear silicon sealant.
Apply the sealant to the body of the connector plug, as
shown in the diagram, before inserting it into its socket,
and replacing the retaining plate and screws.