Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Ładowarka CTEK 1046. CTEK 1046 8 stron. Professional switch mode battery charger

CONNECT ThE ChARGER TO A BATTERY
Comfort
Connect
+
+
Comfort
Connect
6 • EN
INFO
If the battery clamps are incorrectly
connected, the reverse polarity
protection will ensure that the battery
and charger are not damaged.
For batteries mounted inside a
vehicle
1. Connect the red clamp to the battery's
positive pole.
2. Connect the black clamp to the vehicle
chassis remote from the fuel pipe and
the battery.
3. Connect the charger to the wall socket.
4. Disconnect the charger from the wall
socket before disconnecting the battery.
5. Disconnect the black clamp before the
red clamp.

ChARGING PROGRAMS

Settings are made by pressing the MODE-button. After about two seconds the charger
activates the selected program. The selected program will be restarted next time the
charger is connected.
The table explains the different Charging Programs:
Battery
Program
Size (Ah)
Normal battery program
20–300Ah
14.4V/10A. Use for WET batteries,
Ca/Ca, MF and for most GEL batteries
AGM battery program 14.7V/10A
AGM
20–300Ah
Use for AGM batteries.
Recond program 15.8V/1.5A
Use to return energy to the empty
WET and Ca/Ca batteries. Recond
20–300Ah
RECOND
your battery once per year and after
deep dischare to maximise lifetime and
capacity. The Recond program adds
STEP 6 to the normal battery program.
Supply program 13.6V/10A
Use as 12V power supply or use for
float maintenance charging when 100%
20–300Ah
capacity of the battery is required.
Supply program activates step 7 without
time or voltage limitation.
WARNING!
The spark protection on the battery charger
is disabled during SUPPLY program.
Explanation
Temp range
-20°C–+50°C
(-4ºF–122ºF)
-20°C–+50°C
(-4ºF–122ºF)
-20°C–+50°C
(-4ºF–122ºF)
-20°C–+50°C
(-4ºF–122ºF)