Directed Electronics Xpresskit DBALL Instrukcja instalacji - Strona 11
Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Akcesoria samochodowe Directed Electronics Xpresskit DBALL. Directed Electronics Xpresskit DBALL 14 stron. Databus all combo bypass module
Również dla Directed Electronics Xpresskit DBALL: Instrukcja instalacji (14 strony)
Platform: DBALL
Firmware: GM5
Feature and Option List
Features Operation
RF Output type
Activate this feature w henever an external RFTD
1
module is used (i.e. Directed SmartStart™**,
XL201 or XL202).
2
Relock when remote starter stops
3
Trunk
4
Aux1
5
Aux2
* Default Option
** RFTD Output must be enabled for Directed SmartStart™ to work properly.
Note: Features 3, 4 and 5 are programmable triggers.
Feature Programming
To enter feature programming routine
-
For vehicles that are not
twice to turn the ignition ON, then press it once more to turn it OFF.
-
Within 5 sec, press and HOLD the integrated programming button (IPB). The orange LED turns ON after 3 seconds. Release the
IPB.
-
The green LED starts flashing slowly one time to indicate the feature number is 1. After a short delay, the red LED flashes rapidly to
indicate the current option of feature 1. It repeats until next action happens.
Changing feature options
-
Press the lock/arm or unlock/disarm button on aftermarket transmitter to change the option of the selected feature.
-
The red LED flashes rapidly the number of times equal to the current option number. After a short delay, the green LED flashes
slowly the number of times to indicate the current feature. It repeats until next action happens.
Accessing another feature
-
Press and release the IPB a number of times to advance from the current feature to the next desired
-
The green LED flashes slowly the number of times equal to the feature number. After a short delay, the red LED flashes rapidly to
indicate the current option of the current feature. It repeats until next action happens.
When the maximum number of feature or option is reached, the LED will starts flashing again from the first feature or option.
Once a feature is programmed
-
Another feature(s) can be programmed.
-
The feature programming can be exited.
Exiting feature programming
-
No activity for 30 seconds; after 30 seconds, the orange LED will turn ON for 2 seconds to confirm exiting.
OR
-
Press and HOLD the IPB for 3 seconds. After 3 seconds, the orange LED will turn ON for 2 seconds to confirm exiting.
The Mobile Integration Systems
Option
No RF Output*
RTD Output
OFF*
ON
No Option
Trunk*
Right Sliding Door
Left Sliding Door
No Option
Trunk
Right Sliding Door*
Left Sliding Door
No Option
Trunk
Right Sliding Door
Left Sliding Door*
Push-to-Start (PTS)
, use the key to turn the ignition ON, then OFF. For PTS vehicles, press the button
Vehicle CAN Bus Integration System
Integrated
Programming
Button (IPB)
feature
.
© 2010 Directed Electronics. All rights reserved.
Rev.: 20101103
Page 11