ABBAKA Hy-Ex 1.4K Instrukcje instalacji - Strona 3

Przeglądaj online lub pobierz pdf Instrukcje instalacji dla Wentylator ABBAKA Hy-Ex 1.4K. ABBAKA Hy-Ex 1.4K 4 stron. Exterior wall or roof mount ventilator

Architectural Kitchen Range Hoods
WARNING: Turn off power at the service box
before wiring.
1. Power supply for the ventilator is 115V AC 60
Hz. See page 2 for specifications.
2. Run electrical cable between the ventilator and
the range hood or ventilator and wall switch. See
Figure 3
3. Remove top enclosure of the ventilator for ac-
cess to the wiring terminal block.
4. Push the electrical cable up through the bottom
knock out of the ventilator body. Pull enough wire
up into the housing to make attachment to the
terminal block.
5. Connect white to "NEU", green to "GND" and
red speed control wire to "LINE". See Figure 4.
Figure 4
Green/Yellow
(Ground)
Brown
White
Black
Black
Blue
Capacitor
DUCT CONNECTIONS
WARNING: To reduce risk of fire, use only metal
ductwork.
1. Use only round metal duct, elbows and transi-
tions; or rectangular ducting having equivalent
area of square inches as per required duct size.
2. Tape all joints with duct tape.
3. Turn on power and check ventilator operation.
4. Make sure damper opens and closes freely.
P.O. Box 215, Bodega Bay, CA 94923 (800) 548-3932 Fax (800) 548-3930
ELECTRICAL CONNECTIONS
Green
White
E-mail: [email protected] http://www.abbaka.com
Figure 3
VENTILATOR
Black
Range Hood
White
Black
IA-031 8/03