CAME 9T90EN Instrukcja instalacji - Strona 6
Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Panel sterowania CAME 9T90EN. CAME 9T90EN 12 stron. Control panel for 230 v - 400 v gearmotors

Lighting and warning devices
Cycle/courtesy lamp (Contact capacity: 230 V - 60 W max.)
With dip switch 16 set to OFF and dip switch 17 set
to ON = Cycle lamp.
5 1 6 1 7 1 8
Lights the area of operation. It remains on from
the start of gate opening to complete closing (including the
automatic closing time).
With dip switch 16 set to ON and dip switch 17 set
to OFF = Courtesy lamp.
5 1 6 1 7 1 8
Lights the area of operation; stays on for a set time
of 330 seconds after an opening command.
Flashing light (contact rated
for: 230V AC - 25W Max.)
Flashes while gate opens
and closes.
Command devices
Stop button ((N.C.) contact)
Gate stop button that excludes automatic closing, to resume
movement press command or transmitter button.
If unused, set DIP-switch 10 to ON.
Key switch selector and/or opening button (N.O. contact)
Opening command
Key switch selector and/or opening button (N.O. contact)
Partial opening for pedestrian passage. The opening time can be
adjusted via the PART. OPEN. The automatic closing time is adju-
stable via DIP-switch 12.
Key switch selector and/or opening button (N.O. contact)
Closing command.
Key switch selector and/or command button (N.O. contact)
Gate opening and closing commands, pressing the button or turning
the key switch selector, the gate inverts its movement or stops
depending on selection made on the DIP switches (see selecting
functions, DIP switches 2-3)
Gate open warning light
Contact rated for: 24 V - 3
W Max.)
Indicates that gate is open.
Gate open warning light
Contact rated for: 24 V - 3
W Max.)
Indicates that gate is
closed.