3DGence DOUBLE P255 Podręcznik konserwacji - Strona 12

Przeglądaj online lub pobierz pdf Podręcznik konserwacji dla Drukarki 3D 3DGence DOUBLE P255. 3DGence DOUBLE P255 19 stron.

3DGence DOUBLE P255 Podręcznik konserwacji
Calibration of XY offsets:
1. Load the model filament (PLA) and support filament (BVOH) by selecting from the printer menu: MATERIALS
→ LOAD MODEL MATERIAL / LOAD SUPPORT MATERIAL and follow the instructions on the display.
2. Print the calibration model in the printer memory by selecting from the printer menu: MENU → ADVANCED
→ MODULE CALIB. → AUTO XY CALIB.
3. After printing the model, select the line on the display on which the model material with the support
material in part X is best covered (fig. 65).
4. Select the CONTINUE button.
5. Select the line on the display on which the model material with the support material in part Y is best covered
(fig. 66).
6. Select the CONTINUE button.
7. Confirm with the SAVE key.
8. Print the calibration model in the printer memory again by selecting from the printer menu: MENU →
ADVANCED → MODULE CALIB. → AUTO XY CALIB. and visually check the offset calibration level:
• if on the middle line the model material coincides with the support material both in the X axis and in the Y axis -
the XY offsets of the dual hotend module are calibrated correctly,
• if the model material does not coincide with the support material both on the X axis and in the Y axis on the middle
line - the XY offsets of the dual hotend module are not calibrated correctly. Calibrate the offsets again in accordance
with points 2 - 7.
3DGence DOUBLE P255 - maintenance activities | version 07.2021
Fig. 65 Automatic offset calibration screen in the X axis
Fig. 66 Automatic offset calibration screen in the Y axis