3E THERMOSALD ISC Skrócona instrukcja obsługi - Strona 17

Przeglądaj online lub pobierz pdf Skrócona instrukcja obsługi dla Kontroler 3E THERMOSALD ISC. 3E THERMOSALD ISC 20 stron. Temperature controller for impulse sealing. modular system

3E THERMOSALD ISC Skrócona instrukcja obsługi
ANNEX D – FAULT AND WARNINGS LIST (CAUSES – REMEDIES)
NOTE - To reset every alarm give external reset command or press reset button RES on the panel
NOTE – when an alarm happens, on the thermoregulator the led red of alarm light; it's possible to know the number
of alarm reading the multilanguage panel or reading the number of lightening of led red and green:
ALARM NUMBER = NR. IMPULSES OF LED GREEN x 10 + NR.IMPULSES LED RED
WARNING - ALARM CAUSES
Remedies
ALARM A TERMOREGULATOR OFF AND DISPLAY OFF
Verify power, Logic supply fault, call the supplying builder.
ALARM B TERMOREGULATOR WITH LED OFF AND DISPLAY ON
Circuit of synchronisme fault, call the supplying builder.
ALARM C TERMOREGULATOR WITH LED ON AND DISPLAY ON AND INDICATION
"3E SRL + THERMOSALD"
Verify cable connection display
F06
DISPLAY EEPROM FLASH WRITE
Switch off and switch on the equipment and call the supplier
F07
A/D CONVERTER
Switch off and switch on the equipment and call the supplier
F08
INTERNAL TRASMISSION I2C-X
Switch off and switch on the equipment
F09
INTERNAL TRASMISSION I2C-EEPR
Switch off and switch on the equipment and verify parameters
F19
RS485 MASTER - CHECKSUM ERROR
Verify checksum selection on the Master or Slave
F20
RS485 SLAVE - CHECKSUM ERROR
Verify checksum selection on the Master or Slave
F21
RS485 SLAVE - OE ERROR-OVERRUN
Following data arrived before reading the previous
F22
RS485 SLAVE - FE ERROR-FRAME ERROR
Data stop bit not arrived
F23
RS485 MASTER – NO ANSWER FROM SLAVE
After a Master calling no answer received from the slave
F24
RS485 SLAVE – TOO DATA REQUESTED FROM MASTER OR WRONG ADDRESS
Master ha s requested to the slave too many data or a wrong address
F25
RS485 SLAVE – BUFFER FULL
Slave Buffer is full because of too many data trasmitted or too frequently trasmitted
F26
RS485 MASTER - OE ERROR-OVERRUN
Following data arrived before reading the previous
F27
RS485 MASTER - FE ERROR-FRAME ERROR
Data stop bit not arrived
F28
RS485 MASTER - TOO DATA REQUESTED FROM SLAVE OR WRONG ADDRESS
Slave ha s requested to the master too many data or a wrong address
F29
RS485 MASTER - BUFFER FULL
Master Buffer is full because of too many data trasmitted from the slave
F33
NO VOLTAGE ON POWER TRASFORMER
Verify power on CN1/L1,L2, verify power trasformer circuit
F34
DON'T USE
F35
CALIBRATION REQUEST
THERMOSALD ISC – MANUAL QUICK START
Manual cod.: 3ES080x_V5.1_QS_EN
Includes all previous models
Page Nr.
17
Rev. 2010 / 03
Tot. Nr . 20