2.
Use the Board as Factory Programmed
Note: The CY3203A board is preprogrammed as an LCD with seven buttons and a slider. When powered by a
PSoC MiniProg, the LCD displays a graphical representation of the button(s) that are being pressed and where
the finger is at on the slider.
These instructions assume your board has not been reprogrammed from the factory settings. If it has, and you
would like to follow along with this demonstration, follow the instructions in the
Factory Programming section on page
Power the Board
2.1.
Connect your computer to the CapSense test board ISSP Connector (J2)
MiniProg and a USB cable. If this is your first time using the MiniProg, you will need to install the driver
using these steps before proceeding:
a. When the Found New Hardware Wizard opens, select one of the Yes options and click Next.
b. Select the Install the software automatically (Recommended) option and click Next.
c. A warning message may tell you the software you are trying to install has not passed Windows Logo
testing. Click Continue Anyway each time it appears.
d. When the installation is complete, click Finish.
2.2.
Open PSoC Programmer by going to the Windows Start menu and selecting All Programs
Cypress MicroSystems
2.3.
From the Port menu, select MiniProg1/<Identification Code>.
2.4.
Click Toggle Device Power. The D0 LED on the board lights red.
CY3203A-CapSense Quick Start Guide, Spec. # 001-17826 Rev. *A
8, and then start this example with the
PSoC Programming
Resetting the Board to the Original
Power the Board
PSoC Programmer.
section below.
using the PSoC
7