Cypress EZ-PD CY4533 Podręcznik - Strona 14
Przeglądaj online lub pobierz pdf Podręcznik dla Płyta główna Cypress EZ-PD CY4533. Cypress EZ-PD CY4533 20 stron. Barrel connector replacement (bcr) evaluation kit
2.
If all three conditions are satisfied, then BCR sends a request for this PDO with Operating Current set to ISNK_COARSE
+ ISNK_FINE.
3.
If any condition is not satisfied, the BCR device requests 5V (PDO #1) with 900mA Operating Current. The BCR device
also sets the Capability Mismatch flag in the request message.
Once this mismatch of capabilities is detected, FAULT goes HIGH (3.3V strong drive) and the "Safe 5V" load
a.
switch (Q2) turns ON.
To modify the VBUS_MAX value, use the rotary switch. To modify the VBUS_MIN, ISNK_COARSE, and ISNK_FINE
values, mount the correct resistor on the bottom of the board.
See the layout design files on the CY4533 EZ-PD
CY4533 EZ-PD™ BCR Evaluation Kit Guide, Document Number: 002-25263 Rev. *B
TM
BCR Evaluation Kit webpage.
Hardware
14