PODIUM MOUNTED AUTOMATIC GEL HAND SANITIZER DISPENSER (HSD) INSTALLATION GUIDE (Pg 4 of 4)
PROBLEM
INDICATOR
Supply quantity
Low volume dispense
diminished
Red light in the sensor flashes
continuously when the user's
hands are within the sensor
range
No supply dispensed
No supply coming
out of the spout
Red light in the sensor does
not flash (once) when user 's
hands are within the sensor
range
Red light flashes (once) and
the motor operates.
Supply dispensing
Steady stream of droplets is
from the spout
dispensing.
continuously
THIS MANUFACTURER RESERVES THE RIGHT TO MAKE CHANGES IN DESIGN OR DIMENSIONS WITHOUT FORMAL NOTICE
CAUSE
Voltage of batteries is low
Voltage of batteries likely below
1.47V per cell
Supply level is below supply tube.
The tank has been filled but supply
has not reached the spout.
The connector between the motor
and the dispenser head is not
properly engaged.
Sensor is picking up reflections
from another object
Connectors between the dispenser
head and the pump assembly and/or
the power supply are disconnected
or not properly connected.
Batteries are completely depleted.
Supply solidification at the supply
tube.
The Com Cable between the pump
assembly and soap dispenser is not
connected properly.
MODEL №:
ISSUED:
REVISED:
SOLUTION
Replace batteries
Replace batteries
Refill supply tank
Press the refill button on the pump
until supply starts to come out of the
spout again, or press remote "Fill"
button.
Connect the Com Cable plug and
socket properly so that the white O-
ring is not visible.
Eliminate cause of reflection
Connect the plugs and sockets
correctly.
Replace batteries
Fill the tank with warm water at
120~140°F (49-60°C) and run the
pump constantly until supply is
dispensed
Connect the Com Cable plug and
socket properly so that the white O-
ring is not visible.